00193325-01 - 第40页

3 Graphical user int erface SIPLACE Software Guide SR.503.xx 3.3 User interf ace - views and menus Issue 12/01 E N 40 3.3.2.3 „ Options“ menu The "Opti ons" menu is o nly ava ilable i n the m ain view. This men…

100%1 / 124
SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
39
Matrix-tray changer (only for S-25 HM) 3
In order to move to the view for the Siplace Matrix-tray changer you must click the 3
button (Location 1 or Location 3).
Or, from the "View" menu, select the "Feeder" function, and activate the button for MTC in the
dialog displayed. The following window opens.
3
Fig. 3.3 - 3 "Matrix Tray Changer" view (S-25 HM)
3
Key to Fig. 3.3 - 3
(1) Cassette number
(2) Tower number
(3) Level number
(4) Selects the "MTC" view.
(5) Help system for the topic „MTC“
You will find a detailed description of the MTC in the Station Operating Manual. Please refer to the
Online Help for parameter descriptions..
1
32
5
4
3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
40
3.3.2.3 Options“ menu
The "Options" menu is only available in the main view. This menu contains all the supplementary
functions. 3
Click the required menu item and then make the appropriate settings or selections in the cor-
responding windows or dialog boxes.
Machine options... (HS-50) 3
Depending on access level, you can obtain information about the station configuration ("Opera-
tor") or activate or deactivate the displayed machine options ("Line engineer", "Service"). 3
Click the Machine options... menu item (or the appropriate button in the working area of the
main view). The following window is displayed.
3
Fig. 3.3 - 4 „Machine options - entire machine“ dialog box (Example: HS-50)
NOTE
Only those machine options are displayed which are configured at the current station. 3
SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
41
Click the checkboxes corresponding to the machine options which you want to activate or de-
activate.
When the machine is switched off, all options are reset except those listed below:
Comp. verification with barcode
Feeder position recognition
PCB data transfer from PA1(„Whispering Down the line“)
NOTE
At "Operator" access level, it is only possible to activate and deactivate the conveyor interface op-
tions. 3
If you want to activate or deactivate the options for a processing area or view its configuration,
click the Processing area 1 or Processing area 2 tab to select the required area.
The display switches to the selected processing area (see example below for PA1).
3
Fig. 3.3 - 5 „Machine options - Processing area 1" dialog box (Example: HS50)
Activate/deactivate the checkboxes corresponding to the required machine options.
Click Accept to save the settings.
Machine options... (S25-HM) 3
Depending on access level, you can obtain information about the station configuration ("Opera-
tor") or activate or deactivate the displayed machine options ("Line engineer", "Service"). 3