ASM贴片机SX2机型电路图 - 第14页

electric_schematic_SX12_V3 90013315-010101LE3 Replaced by Assembly overview, TwinHead Replaced by Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung des Inhalts nicht gestattet, soweit nicht au…

100%1 / 135
electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Assembly overview, CPP head
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview Graphics
==OVGR=SX12_V3/8
drawing number:
CPP_head
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Schnedlitz
Date
Date
Modification
Appr
12.12.2019
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
8
/
7
M
==HD+CPP_2-M2
CPP star motor
03061531
==HD+CPP_2/93.3
==HD+CPP_2-B2
Rotary encoder
03039363
==HD+CPP_2/93.0
M2
03063184
CPP star drive
==HD+CPP_2-M1.DP
DP-Drive CPP
03050314
==HD+CPP_2/95.0
==HD+CPP_2-M3
CPP Z-axis
03079054
==HD+CPP_2/93.7
==HD+CPP_2-B3
Z axis encoder
03039873
==HD+CPP_2/93.4
M3
Front panel with Z Drive CPP
03061102
==HD+CPP_2-A10
Board Power Unit SCS /CPP
03054771
==HD+CPP_2/95.0
==HD+CPP_2-A11
Board Control Unit SCS /CPP
03054784
==HD+CPP_2/95.5
A6
Star complete CPP
03015702
-A4
Intermediate Distributor 1
ZV1 CPP
03065295
==HD+CPP_2/93.4
-A5
Intermediate Distributor 2
ZV2 CPP
03052586
==HD+CPP_2/94.0
electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Assembly overview, TwinHead
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview Graphics
==OVGR=SX12_V3/9
drawing number:
03097233-010601LX3
Twin_head
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
schnedlitz
Date
Date
Modification
Appr
30.04.2020
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
9
/
7
M
M
Optional:
VHF Twin Head
(High force option)
==HD+TWIN2-A5-A6
Force measurement board-centering
03104142
==HD+TWIN_3/99.2
==HD+TWIN2-M1
Z-axis linear drive
P&P module 1
03092655
==HD+TWIN_3/99.2
==HD+TWIN2-A4
Head mainpoard P+P head
inter-distribution
00352833
==HD+TWIN_3/98.0
==HD+TWIN1-A4
Head mainboard P+P head
inter-distribution
00352833
==HD+TWIN_3/96.0
==HD+TWIN2-B1
Z-axis-encoder
03090205
==HD+TWIN_3/98.5
==HD+TWIN1-A5-A6
Force measurement board-centering
03104142
==HD+TWIN_3/97.2
-M2
DP-Unit P+P - Modul
03014683
-DM2
P310 disc
magnet motor
03014681
==HD+TWIN_3/99.4
-B2
Encoder
P&P module
03000046
==HD+TWIN_3/99.5
-DM2
P310 disc
magnet motor
03014681
==HD+TWIN_3/97.4
-B2
Encoder
P&P module
03000046
==HD+TWIN_3/97.5
-M2
DP-Unit P+P - Modul
03014683
==HD+TWIN1-K1
Pressure
control valve
03058802
==HD+TWIN_3/96.0
==HD+TWIN2-K1
Pressur
control valve
03058802
==HD+TWIN_3/98.0
electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Overview
Power-Supply, switched mode type, SX12
V3
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=SX12_V3+PS002/10
drawing number:
03233467-010101LE3
Power_supply SMPS / CSB
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
maettig
Date
Date
Modification
Appr
12.05.2020
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
10
/
1
Serialize digital inputs
Data bus level adjust done by optocouplers
Signal level: 24 V unipolar
RED: individual voltage monitoring (on Board)
RS485
driver
CLKSDATACS
32 bits
GREEN: Diagnostic OK
DC Voltage conversion
27V --> 24 V / 100 W
. . . . .
not usednot used
ITS4141
Load-switch
=~
=
+ -
LOGIC
1 | Autostart/Monitored Start
2 | Cross Fault Detection Off/On
3 | 2 single ch. sensors / 1 double channel Sensor
4 | Startup Test Yes/No
SET / RESET
T
-K5
Safety relay 2-chanel
24V AC
03114826-
==CSB+/46.03
Siemens
3SK1121-xCB41
Mains testing
terminals
-X1
-S1
Main power switch
==PS002+/42.06
3
-X94
00335210
-W1
-X95
-X101-X101BR
Supply Bridge (Plug)
-X302
03110977
-W2.1
03110977
-W2.2
-PS1
Power Supply 3AC 380-480V
Uout = 300 V DC / 160 V DC
03103087
==PS002+/43.01
L1/L2/L3
-CAP1
DC 300/150
Capcitor Bank
03103081
==PS002+/43.00
-X1.CAP1
QT40 Diagnostic
Power connection PS1
160V/300V
03110978
-W3.1
-X3.CAP1
Power
-PS2
Conveyor and Head supply
Uout = 42 V +/- 500mV
03103331
==PS002+/44.00
3AC 380-480V
DC-out 42V
-X1.PS1
-X1
Power DC-Out
160V/300V
-X2
Diagnostic Interface
-X2.PS1
03110979
-W4.1
-PS3
Electronics supply
Uout = 27 V +/- 200 mV
03104141
==PS002+/44.02
3AC 380-480V
DC-out 27V
-X1
Diagnostic 1
-X3
DC-IN
160V/300V
-FD.A1
Fuse and distribution
03104070
==PS002+/44.00
-X25.FD
DC 42V in
Cable PS2 output
03110991
-W7
-X25
DC 42 V in
-X26.FD
DC 27 V IN
Cable PS3 output
03110992
-W8
-X26
DC 27 V in
-X2.CAP1
-X2
DC-Power out
160V/300V
-F1
-F2
-F3
-X2
Diagnostic
serial interface
-XB8a
Gantry-1
DC160V
-XB8b
Gantry-2
DC160V
-X24B
Control
Cable
Connection FDB
03110984
-W6.2
-X24B.FD
Control
-X2
-F1
Line protection
16 A C
==PS002+/42.06
3
-X24B.CSB -X21.CSB -X22B.CSB-X29.CSB -X30.CSB
-XB8aqy -XB8b.FD
-X5
FCU 1&2
DC 27V
-XB1a
Gantry-1
24V & Signals
-XB1b
Gantry-2
24V & Signals
-XB5b
GCU3 supply
-XB5a
GCU1 GCU2 supply
-XB4
Conveyor
-XB2
Power Distributor
& PC 3D-Sensor
-X2.FD -XB1a.FD -XB1bqy -XB5aqy -XB5b.FD -XB4qy
-F23
Cable DC Power CAP1
03110981
-W5.1
-X5.FD
-X24B.FD
Control
-X24A.CSB
Cable
Connection FDB
03110984
-W6.1
-X24A
Star Voltage
-X19.CSB
-X19.CSB
-X304
TP2 Service Testing point
DC300 PCS417
-X303
Service Testing point
DC300 PS1/QT40
-X0
Diagnostic
Master
-X0.CAP1
-X96
24V.PCC
PCC supply
undervoltage
lockout
24V0
24V_PCC
-A2
Safety breaker unit
PCB Pre-/discharge assembly
03108631
==CSB+/46.00
K1, K2, K3, K4
Relais Safety
300/160/42/24V
==CSB+/46.06
-X27.CSB
-X27
-X100.CSB
-X100
-X28.CSB
K1, K2
24V_AUX
==CSB+/46.06
-K2
Start B
==CSB+/46.02
+
+
-
-K3
Start A
==CSB+/46.02
+
+
-
-X28
-X21
300V Power
-X22
300V Power
-X22B
300V Power
-X29 -X30 -X31
-X25.CSB
-X25
Low voltage control
-X26
Pre/Discharge control
-X26.CSB
-X20
Power-in
300V, 160V
-X20.CSB
-K2
Safety Switch
300/160V
Power enable
==CSB+/46.07
-K1
Safety Switch
300/160V
==CSB+/46.06
-K4
Discharge/Precharge
160/300V
==CSB+/46.08
-K3
Safety_Switch 24V
==CSB+/46.07
-K3
Safety_Switch 42V
==CSB+/46.07
Single-wire
Safaty-signals Safaty-signals
+160V
+300V
Single-wire
Single-wire
Single-wire
Single-wire
-X24B
Safety
control signals
42V IN/OUT
-X24A
Safety
switched 160V
P300V
P160V
-PPWR.PRESENT
Voltage-Trigger
300V/160V PPWR-present
(300V > 60V && 160V > 60V)
==CSB+/46.06
-X19.CSB
-K1
Safety loop
closed signal
==CSB+/46.02
+
+
-
-F1
PrechargingDischarge
Single-wire
K1, K2, K3, K4
Test_Loop_In
==CSB+/46.06
==CSB+#
Control-box Safety Bracker
030112066
-T1
Transformer
3P208V/400V/5,05A
==PS002+/42.00
-A100
Inrush
current limiter
==PS002+/42.00
-OPT_LowVoltage
Low Voltage adaption kit (Option)
3P208V/400V/5,05A
#03118051
==PS002+/42.00
F1/F2/F3
Fuse 6,3 A T
3
200 V
R1/R2/R3
400 V
-X101.TR
- Optional-Connection -
Low Voltage
Option
Converter
Connection
200 V input
1U
-X98
-X103-X105
#03232247
retrofitkit_vacuumpump_IE3_SX12_V3
-X103
-X105
-K1
SIE.3RT2015-1FB42
-RC1
SIE.3RT19 16-1PA1
-M1
3+PE
3~
M
==FLUID+-VAC1
Pneumauic view
==FLUID+/129.04
-B1
bimetallic-switch
150°C
-VACP1
vacuum pump Becker VX4.25_IE3
0,75KW, 25m³/h
03211684
==PS002+VAC_P/45.04
==PS002+VAC_P/45.05
power supply
03231317
-W1
-X1.VP
-X1.VP
03202514
-W1
-QM1
SIE.3RV2011-1DA10
3
I>
-X106
-X106
-qr
+03232030-qr
Vacuum Pump Control
SX12 V3
==PS002+VAC_P/45.01
==PS002+VAC_P/45.05
Vacuum-Pump IE3
Extension-Cable
03231357
-W1
==PS002+VAC_P/45.02
Control Vacuum Pump
03072544
-W1
-MGP-PE
Main_ground_point
X301
4
MGP
X1
3
MGP
X1
2
MGP
X1
1
MGP
PE
X94
5
MGP
X95
4
MGP
X98
3
PE
PWR.300V_160V
/10.09
DIAG.S
+CH/11.07
To Software diagnosti IOCU
cexternal connection
MGCU1&2_300V
+GA/24.04
DC160V_GA1
+GA/24.07
Head-supply
To Gantry interface 1
POWER.DI
+CH/11.06
PC & Distributor DC 27 V
supply_GA2
+GA/25.07
Gantry_supply
supply_GA1
+GA/24.07
Gantry_supply
Control_GCU1_2
+GA/24.06
GCU_supply DC 27V
Control_GCU3
+GA/25.06
GCU_supply DC 27V
CO_Power
+CH/11.08
Conveyor DC 24V / 42V
MC_PE
wiring general protection earth
+PE/41.05
MGCU3_300V
+GA/25.04
DC160V_GA2
+GA/25.07
Head-supply
To Gantry interface 2
Safety_Loop.DI
+CH/11.05
Safety_Sig.DI
+CH/11.05
POWER.COTi
+CH/11.08
FCU 1&2 DC 27V
Diagnostic.CAP1
+CH/11.08
USE 100 or 1000 Base-T
PWR.300V_160V
==PS002+CSB-X19.CSB /10.01
P300VP300V
P160VP160V
Control_VAC_Pump
to X17qa (Distributor)