ASM贴片机SX2机型电路图 - 第20页
electric_schematic_SX12_V3 90013315-010101LE3 Replaced by Block_diagram COT-i 30 _Loc1_2 FCU_Gerneral / Docking_unit / reject_box Replaced by Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung …

electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Block_diagram IC & FC stationary cameras
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=SX12_V3+stCAM/14
drawing number:
03055284-030401LE3
Cable_harness IC&FC Camera
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Schnedlitz
Date
Date
Modification
Appr
12.12.2019
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
14
/
1
Wiring example for
IC camera stationary and
FC camera stationary
Location 1
Wiring example for
IC camera stationary and
FC camera stationary
Location 2
-FC2-cm
Vision LED controller
VLC25 GigE
03117587-xx
-X4
Power in
-X10
MCAN
-IC2-bm
Vision LED controller
VLC33/36 GigE
03117981-xx
-X5
Power out
-X10
MCAN
-IC2
CO camera stat. P+P
(Type 33) 55x45 GigE
03105198
-FC2
CO camera stat. P+P
(Type 25) 16x16 GigE
03105205
-X4
Power in
-X22.2
RJ45
-X22.1
RJ45
-X5
Power out
-X22.2_FC2
-X5bm
-X4cm
Extension power FC camera
03106368
-W1.2
4G1,0
-X10cm
-IC2-CAM
CCD-Camera
Baumer GSX20
03103549-xx
-X2
RJ45
-X2
-X1-X31
-FC2-CAM
CCD-Camera
Baumer GSX20
03103549-01
-X1
-X2
RJ45
-X31
-X21
RJ45
-X21.mm
-X2
I/O-cable
VLC25/33-GXS20 GigE
03106364
-FC2-W1
I/O-cable
VLC25/33-GXS20 GigE
03106364
-IC2-W1
Extension camera bus IC FC camera
03106367
-W1.2
Extension camera bus IC FC camera
03106367
-W1.1
-FC1-dm
Vision LED controller
VLC25 GigE
03117587-xx
-X4
Power in
-X10
MCAN
-IC1-am
Vision LED controller
VLC33/36 GigE
03117981-xx
-X5
Power out
-X10
MCAN
-IC1
CO camera stat. P+P
(Type 33) 55x45 GigE
03105198
-FC1
CO camera stat. P+P
(Type 25) 16x16 GigE
03105205
-X4
Power in
-X22.2
RJ45
-X22.1
RJ45
-X5
Power out
-X22.2_FC1
-X5am
-X4dm
Extension power FC camera
03106368
-W1.2
4G1,0
-X10dm
-IC1-CAM
CCD-Camera
Baumer GSX20
03103549-xx
-X2
RJ45
-X2
-X1-X31
-FC1-CAM
CCD-Camera
Baumer GSX20
03103549-01
-X1
-X2
RJ45
-X31
-X21
RJ45
-X21.mm
-X2
I/O-cable
VLC25/33-GXS20 GigE
03106364
-FC2-W1
I/O-cable
VLC25/33-GXS20 GigE
03106364
-IC2-W1
Extension camera bus IC FC camera
03106367
-W1.2
Extension camera bus IC FC camera
03106367
-W1.1
-X10am -X10bm-X4am -X4bm
-X22.1_FC2-X22.1_FC1
==stCAM=+Loc2-Power
+CH/12.03
==stCAM=+Loc1-Power
+CH/12.03
==stCAM+Loc2-CAN.VLC25
Vision Base Interface (VBI_2)
+GA/25.09
==stCAM+Loc1-CAN.VLC25
Vision Base Interface (VBI_1)
+GA/24.09
==IC=+Loc1-CAN.2
+CH/13.08
==IC=+Loc2-CAN.2
+CH/13.05
==FC=+Loc2-CAN.2
+CH/13.05
==FC=+Loc1-CAN.1
+CH/13.08

electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Block_diagram COT-i 30 _Loc1_2
FCU_Gerneral / Docking_unit / reject_box
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=SX12_V3+COTi30/15
drawing number:
03078847-020301LX3
COT-i 30 + WPC
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Schnedlitz
Date
Date
Modification
Appr
12.12.2019
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
15
/
3
location 1_2
(WPC / SPS)
Cable-harness
Cable-harness
Reject bin
03081265
Reject bin
03063238
OR
Reject bin
03003719
Reject bin
03062378
Reject bin
03062378
COTi_30
location 1_2
DIP-Switch position for:
> COT-insert 30_WPC
-Y1
SP1_X..
-fp
-hp = Location 2
X-FCU (80MHz), 60 slots
03170631-xx
Location 1_2 (WPC)
03170631
-X11
Feeder
unlock device
-X21
Sensors
reject box
[left]
-X22
Sensors
reject box
[right]
-X23
Nozzle
station
-X24
24V-switched
[Tape cutter]
-X1
-X7
Power
-X3
CAN_1
[Base machine]
-X16
CAN_2
[IrDA-CAN]
-X17
CAN_3
[CAN-Open]
-X11
Location addressing
and Identification
-X1
-X25
S_Hood
[COT-insert control]
-X4
Feeder unlock
push-button
-X13
COT-insert control
-X26
24V output
-X19
FCU-Ready
-le
Feeder unlock device 60-way
03057772-01
-X1
Feeder
unlock device
20x0.09
03072088
-W1
Cable COT_insert_30
Feeder_unlock_device
-X11_p
-X1
5x0,23
03079413
-W1
Cable COT-insert 30
Sensors reject box
-X21_p
-X1_n
-X21*a
-X21*a
-X23_p
-X1_1
Power
-X7_p
5G1,5
03072087
-W1
Cable COT-insert 30 _ Power
-X1_5
CAN1_In
10x0,09
03072093
-W1.1
Cable COT-insert 30 _ CAN
-X3_p -X11_p(X1) -X25_p -X24_p
-X1_2
Signaling
7x0,34
03079167
-W1.1
Cable COT-insert 30 _ Signaling
-lc
PCB /Insert-Control SX12
03118186
-X2
S_Hood
-X3
S_Retracted
Valve_out
-X4
Valve_out
-X1
S_Retracted
2x0,23
03079167
-W1.2
Cable COT-insert 30 _ Signaling
3x0,34
03079166
-W1.2
Cable COT-insert 30 _ Insert control in/out
-Y1
Double solenoid valve
03002003
FESTO _ CPE14-M1BH-5J-1/8-SA
-X1_out_14
Y1_out
-X1_in_12
Y1_in
-X1_out_14
-X4lc
2x0,25
03079165
-W1
Cable COT-insert 30
Insert control out
-X1_in_12
2x0,25
03079166
-W1.1
Cable COT-insert 30
Insert control in/out
-S1p
Safety switch MT-GD2
with separate actuator
03075831-01
440K-MT55002
4x0,34
03079164
-W1.1
Cable COT-insert 30 _ Safety
2x0,34
03079164
-W1.2
Cable COT-insert 30 _ Safety
-X1lc
-X1_3
Safety
-X13_p(X1)
-X2lc -X3lc
-X1-n
-S2
S2_component
Operation from the front
03053232
2x0,25
03077546
-W1.2
Cable COT-insert 30
Sensors reject box
2x0,25
03077546
-W1.1
Cable COT-insert 30
Sensors reject box
2x0,25
03072090
-W1
Cable Manual Table 30
Valve nozzle station
-S1_S2
Cable SX
Sensors reject box “left” CP20/CPP
03077546
-S1
S1_component
Operation from the front
03053232
FESTO-Ventil
557577
03051469
-Y2
Valve
nozzle station
03051469
-X1_p
CAN1_Out
10x0,09
03072093
-W1.2
Cable COT-insert 30 _ CAN
5x0,23
03079413
-W2
Cable COT-insert 30
Sensors reject box
-X22_p
-X2_n
-X2_n
2x0,25
03060826
-W1.2
Cable COT-insert 30
Sensors reject box
2x0,25
03060826
-W1.1
Cable COT-insert 60
Sensors reject box
-S1_S2
Cable SX
Sensors reject box “right” CP20/CPP
03060826
-S1
S1_component
Operation from the front
03053232
-S2
S2_nozzle
Operation from the front
03053232
-X13qa
Component_Table_1 (COTi1)
safety and signalling
COT-insert 1
-X13qa
7x0,5
03052268
-W1.2
7x0,5
Single core
03052268
-W1.2
-X112
-X113
-qa
==PS002+VAC_P/45.01
==COTi30+Loc1_2-MTC
/17.06
CAN-IN to MTC1 + optional MTC2
==COTi30+Loc1-POWER_COTi.30
+CH/11.08
from Power-supply -qp-PS1/X4qp
==COTi30+Loc2-POWER_COTi.30
+CH/11.09
from Power-supply -qp-PS1/X5qp
==COTi30+Loc1-MCAN.1
+CH/13.09
==COTi30+Loc2-MCAN.2
+CH/13.04

electric_schematic_SX12_V3
90013315-010101LE3
Replaced by
Block_diagram COT-i 30 _Loc1_2
1x NC
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=SX12_V3+COTi30/16
drawing number:
03078847-020301LX3
COT-i 30 + WPC
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Schnedlitz
Date
Date
Modification
Appr
12.12.2019
Name
starting MC-Nr.: 2018/Q3 G. Pingist
Size DIN A2
Sheet
16
/
3
First row -->
End position sensor Cylinder 2 End position sensor Cylinder 1
location 1_2
WPC
-fp
-hp = Location 2
X-FCU (80MHz), 60 slots
03170631-xx
Location 1_2 (WPC)
03170631
-X12
Nozzle changer 1
-X13
Nozzle changer 2
-X14
Nozzle changer 3
-X18
Nozzle changer 4
-X13_p
10x0.14
03072094
-W1
Cable-Nozzle changer
-X5_p(X1)
-X5
Valve 2
[left]
-X1
-X8
Sensor 1
[extended position]
-X7
Sensor 2
[retracted position]
-X9
Sensor 4
[retracted position]
-X10
Sensor 3
[extended position]
-X6
Valve 1
[right]
-X8_p(X1) -X7_p(X1) -X9_p(X1) -X10_p(X1) -X6_p(X1)
-X1_b
NC 2 / SPS 1
-ah
-ch = Location-2
Tape cutter
03063781
-X1_h
16x0,25
03072095
-W1
Cable COT-insert 30 Tape-cutter
-X1
Wago-Stiftleiste
-X6
-fb
Nozzle changer basic assembly
CPx short
03062463-02
(-hb)