00194313-03 - 第52页

2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM 2.2 Requirements 02/2007 Edition 52 – T o assembly the modular head boards, relatively o ld S-23 machines th at have been upgrad ed to S-25 HM …

100%1 / 96
SIPLACE S-25 HM / S-27 HM 2 Assembly Instructions for PCB Camera, Multicolor
02/2007 Edition 2.1 Overview
51
2 Assembly Instructions for PCB
Camera, Multicolor
2.1 Overview
These instructions describe how to assembly the optional "PCB Camera Multicolor" on SIPLACE
S-25 HM and S-27 HM.
The optional PCB camera Multicolor is used in place of the subgantry camera (PCB camera with
normal light) and the optional oblique illumination. It is utilized to improve the recognition of fidu-
cials (reference marks) and therefore to achieve greater accuracy during placement.
With the PCB camera Multicolor it is possible to acquire at least the entire range of fiducials cur-
rently recognizable with normal or oblique illumination.
2.2 Requirements
The assembly has to be done for all gantries. 2
S-25 HM 2
Software version 502.01 or later
Head PCB S-25 HM, modular must be installed for use of camera Multicolor.
If it is not installed, it must be assemblied.
On machines manufactured from Sep 98 to Dec 98 a DIN mounting rail (top-hat rail) has to be
installed on the RH side of the terminal panel. This rail is not included in the assembly kit.
1 Assembly kit "Head PCB S-23 (S-25HM)", modular Item no.: 00359488-01
2 Head PCB S-23 (S-25HM) assembly" (modular) Item no.: 00353198-02
Gantry head distributor S-23 (S-25 HM), modular Item no.: 00344486-01
Processor board 80C515C Item no.: 00344485-01
SM board modular Item no.: 00344488-02
Vision-Board modular Item no.: 00344489-02
2
Cable: Placement head, modular S-25 HM:
2 ribbon cables long, modified, incl. connectors (40-pin)
Item no.: 00358917-01
1
Cable S-25 HM: Illumination for component (camera), modular,
modified, incl. connectors (26 pins), folded repeatedly
Item no.: 00351063-01
1
Assembly instructions G + E "Head PCB assembly, modular,
for S-25 HM and HS-50 "
Item no.: 00192393-01
2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.2 Requirements 02/2007 Edition
52
To assembly the modular head boards, relatively old S-23 machines that have been upgraded
to S-25 HM (Retro) require 3 new 10-pin connectors and 1 new 16-pin connector that have to
be fitted on the existing ribbon cables (see Abb. 2.6.10 and Assembly Instructions "Head PCB,
modular....."). This is necessary to effect the strain relief for the cables.
The Service Center is keeping these parts on hand in a separate package, along with the ne-
cessary special tools (see Section 2.4.2.1).
S-27 HM 2
Software version: 503.01 or later
2
2
SIPLACE S-25 HM / S-27 HM 2 Assembly Instructions for PCB Camera, Multicolor
02/2007 Edition 2.3 Safety Instructions
53
2.3 Safety Instructions
DANGER
Only Siemens service engineers are permitted to perform the assembly of the "PCB camera Mul-
ticolor". Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in
the User Manual and Service Manual.
The machines SIPLACE are powered by line voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine even
while the master switch is turned off.
After you have properly carried out the shut-down of the operating system:
Before all work the machine must be turned off at the main switch and isolated from the mains. In
addition, the compressed air supply must be turned off at the main valve of the compressed air
unit in the machine base and the compressed air lines must be bled by actuating the needle valve
at the compressed air unit (particularly due to the risk of injury - posed by residual air - at the pneu-
matic cutter after undocking/removing the component changeover table).
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see Chapter "Operational Safety").
During the work of assembly secure the machine conscientiously against other personnel and pre-
vent it from being turned back on without authorization, as described in the User Manual in the
chapter "Locking the Machine...".
There is additional, higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so.
For the work with the SITEST program the component changeover table must be moved in and
correctly connected. 2
2
2
2
2
2
2
2