SIPLACE S-25 HM / S-27 HM 2 Assembly Inst ructions for PCB Camera, Multicolor 02/2007 Edition 2.3 Configuration PCB Camera Multicolor on L C 77 2.3.1 Camera Focus, dependent on PCB/Substrate Thickness The focus level for…

100%1 / 96
2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.3 Configuration PCB Camera Multicolor on LC 02/2007 Edition
76
: The field "PCB camera Multicolor" is deactivated. Activate the optional PCB camera Multicolor
with a double click on "LP PC_cam _18", as illustrated above.
: Do this for all 4 / 2 gantries (HS-50 / S-25 HM).
: In the menu bar at top, in the Station Editor, select "File" -> "Save" - END".
: Then select: "File" -> "Data manager".
: Double click on the ICONs for "Master data".
: In the window that opens, double click on "Stations".
: Click once on the "Double click" field that opens and click once on "Compiler" to select it
and
: continue with a double click to select the pertinent station at which the PCB camera Multicolor
is used / was assemblied.
: In the "Data manager" window select the field "OK".
All of the windows are closed.
This concludes the work on the line computer for the configuration of the PCB camera Multi-
color. If you have not done so already, carry out the check "Camera Focus.... Substrate thick-
ness" as described in Abschn. 2.3.1. After this step continue with the activation/ configuration
and the illumination check (see Abschn. 2.4).
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
SIPLACE S-25 HM / S-27 HM 2 Assembly Instructions for PCB Camera, Multicolor
02/2007 Edition 2.3 Configuration PCB Camera Multicolor on LC
77
2.3.1 Camera Focus, dependent on PCB/Substrate Thickness
The focus level for the current substrate or PCB thickness can be optimized by installing or remo-
ving the distance plate (spacer) between the Multicolor PCB camera and camera holder. 2
The decision as to whether or not to work with the distance plate can be made during the course
of the assembly on the basis of the table (see Abschn. 2.2.2). As a final check, a specification can
be accessed at the line computer as described below: 2
: After describing the PCB, including entering the PCB/substrate thickness (= height) in the clu-
ster editor, conducting the produceability check and specifying the job for the relevant station
in the job editor you can check under -> Services -> Error messages.
If a change must be made involving the distance plate (spacer), a message such as the follo-
wing one is displayed:
Warning: PCB xxx.la is more than 3.400 mm thick (x.y > 3.400 mm)
For this reason, camera 18 must be mounted without the spacer.
or
Warning: PCB xxx.la is less than 1.500 mm thick (x.y < 1.500 mm).
For this reason, camera 18 must be mounted with the spacer.
xxx.la = name of PCB
x.y = in the cluster editor entered thickness (height) of the PCB / substrate
Camera 18 = PCB camera Multicolor
: Continue with the activation / configuration and the illumination check (see Abschn. 2.4).
2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 02/2007 Edition
78
2.4 SITEST: Configuration and Illumination Check of
all PCB Cameras Multicolor
The configuration of the PCB Camera Multicolor can be performed before or after the configura-
tion in the station configurator of the UNIX line computer. 2
DANGER
During the following work, pay attention to the DANGER text regarding work with the SITEST pro-
gram in Abschn. 2.3. 2
2.10.1 Configuration
The Requirement for the configuration is that the 4 PCB cameras Multicolor are assemblied on
the HS-50 or the both PCB cameras Multicolor are assemblied on the S-25 HM and the safety
hoods and safety doors are closed.
All component changeover tables must be moved into the machined and docked properly. 2
: Boot the machine and change over into the SITEST program.
: Select "Settings" -> "Machine configuration".
: On the HS-50 or S-25 HM select: "Gantry 1" -> "PCB camera" -> "Edit" (button).
2
2
2
2
2
2
2
2
2
2
2