SIPLACE S-25 HM / S-27 HM 2 Assembly Inst ructions for PCB Camera, Multicolor 02/2007 Edition 2.4 SITEST: Configuration and Il lumination Check of all PCB Cameras Multicolor 79 : The "Edit" window is displa yed…

100%1 / 96
2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 02/2007 Edition
78
2.4 SITEST: Configuration and Illumination Check of
all PCB Cameras Multicolor
The configuration of the PCB Camera Multicolor can be performed before or after the configura-
tion in the station configurator of the UNIX line computer. 2
DANGER
During the following work, pay attention to the DANGER text regarding work with the SITEST pro-
gram in Abschn. 2.3. 2
2.10.1 Configuration
The Requirement for the configuration is that the 4 PCB cameras Multicolor are assemblied on
the HS-50 or the both PCB cameras Multicolor are assemblied on the S-25 HM and the safety
hoods and safety doors are closed.
All component changeover tables must be moved into the machined and docked properly. 2
: Boot the machine and change over into the SITEST program.
: Select "Settings" -> "Machine configuration".
: On the HS-50 or S-25 HM select: "Gantry 1" -> "PCB camera" -> "Edit" (button).
2
2
2
2
2
2
2
2
2
2
2
SIPLACE S-25 HM / S-27 HM 2 Assembly Instructions for PCB Camera, Multicolor
02/2007 Edition 2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor
79
: The "Edit" window is displayed (e.g., on the HS-50):
Fig. 2.10.1 "Edit" Window: Selecting the PCB Camera Multicolor
: In the configuration menu of gantry 1, mark the option "Multicolor" and select "Accept" (button).
: Select the PCB camera Multicolor for gantry 2 and "Accept" this camera.
: Conduct the illumination check for the PCB cameras Multicolor as described below in Abschn.
2.10.2.
: Exit the menu "Machine configuration" by pressing "Accept".
: Power down the machine and execute a new start so that the configuration will be accepted.
: Next, return to the SITEST program.
: In the main view, press the button "Total reference run".
: Afterwards, conduct the calibration:
Whenever the PCB camera Multicolor is assemblied, reinstalled or exchanged, all of the pla-
cement heads and cameras must be calibrated - after the overall reference run - as described
in the User Manual SITEST SW V 502.xx.
2 Assembly Instructions for PCB Camera, Multicolor SIPLACE S-25 HM / S-27 HM
2.4 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 02/2007 Edition
80
2.10.2 Illumination Check
NOTE:
We recommend that you conduct the illumination check be performed after the PCB camera Mul-
ticolor is assemblied, reinstalled or exchanged. By appropriately switching over the vision screen
(see User Manual) it is possible to precisely check the function of the pertinent light level and, for
example, the change from full to one-half brightness. 2
2
: In the SITEST program 502.xx select the ICON "Gantries" and then the "Gantry 1" .
: Click on the CON "PCB camera functions" .
The following screen is displayed (using S-25 HM as an example):
Fig. 2.10.2 Menu "Setting of Illumination" for PCB Camera"
2
2