3 Installation
3.3 Final Work
58 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
Fit the cover plate (1) at the machine base.
NOTICE
Input pressure manometer
Set the manometer of the maintenance unit to an input pressure of 3.5 bar (max. permiss-
ible are 4.2 bar).
Setting of the vacuum switches: At a vacuum of
0.1 bar (100 mbar) with a hysteresis of 0.05 bar
(50 mbar), the lifting table should sink.
At 0.45 bar (450 mbar) with a hysteresis of 0.05
bar (50 mbar), the placement should start.
Perform the setting with the MODE button (1) and
SET button (2); please refer to the enclosed
Schmalz instructions for the vacuum switch
[30.30.01.00997/1 - 04.2016].
3 Installation
3.3 Final Work
Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017 59
3.3.1 Settings in the Vacuum Switch
Fig.4: Vacuum switch
1. Fluid connection
2. Switching point 1 display, ORANGE or operating voltage display, GREEN
3. MODE button
4. Display
5. Position of the NFC antenna behind the display
6. SET button
7. Switching point 2 display, ORANGE
8. Electrical connection M12-4 or M8-4
Basic operation:
Press the SET button for the basic menu.
To scroll forward, press the SET button.
To select a menu item, press the MODE button.
You can quit or cancel the menus as follows:
Press both SET and MODE buttons.
Do not press any button for 1 minute.
3 Installation
3.3 Final Work
60 Montageanleitung / Assembly Instructions SIPLACE TX-Serie Basic Pack Vacuum Tooling 07/2017
3.3.1.1 Factory Settings
Parameter VSi-V VSi-P10 VSi-VP8
Switching point 1
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP1 750 mbar 5500 mbar -750 mbar
Reset point rP1 600 mbar 5000 mbar -600 mbar
Window hysteresis Hy1 / leakage limit per sec L-1 20 mbar 100 mbar 20 mbar
Switch-on delay dS1, switch-off delay dr1 0ms 0ms 0ms
Switching point 2
Switching point mode and logic Two-point mode, normally closed (H.
no)
Switching point SP2 550 mbar 5000 mbar 5500 mbar
Reset point rP2 500 mbar 4500 mbar 5000 mbar
Window hysteresis Hy2 / leakage limit per sec L-2 20 mbar 100 mbar 20 mbar
Switch-on delay dS2, switch-off delay dr2 0ms 0ms 0ms
Transistor function PNP PNP PNP
Display unit mbar mbar mbar
Eco mode Off Off Off
Display alignment Standard Standard Standard
IO link device locks, extended device locks 0 0 0
Menu PIN code, NFC PIN code 000 000 000