CP6的IO代码 - 第97页
1.7 Cleaning the T apered Clutches at Nozzle Rotation Axes (Every Month) Point Following extended periods of operation, the tapered clutches at the nozzle rotation axes can become spattered with grease, etc., from the ma…

1.6 Cleaning the Prism Surfaces (Every Week)
Point
Oil or dirt on the surfaces of the prisms can lead to problems such as reduced light
strength and distortion of the image. This may affect the placing accuracy.
Procedure
WARNING
Always be sure to cut off the 200 V power before carrying out any
work.
Wipe the prism surfaces clean with clean gauze once a week.
Part 3 Chapter 1 Cleaning
Edition 1.1 3-1-5 CP-6-series Mechanical Reference

1.7 Cleaning the Tapered Clutches at Nozzle Rotation
Axes (Every Month)
Point
Following extended periods of operation, the tapered clutches at the nozzle rotation axes
can become spattered with grease, etc., from the machine, causing the clutches to slip. A
slipping clutch makes it difficult to rotate and position a nozzle at the proper mounting
angle. The clutches should therefore be cleaned regularly, using the grease cleaner
(ThreeBond 2706) provided with the machine.
Procedure
WARNING
• Always be sure to cut off the 200 V power before carrying out any
work.
• Exercise extreme caution when working on the machine if the cam is
not at its origin (0 deg.). Recoil of the cam axis can endanger the
operator.
Pull the outer shaft of the nozzle rotation axis downward, then wipe the tapered clutch
clean using a cloth which has been wetted with grease cleaner.
Note: Do not spray the grease cleaner directly on the tapered clutch because the cleaner could
land on other parts as well, removing their lubricant.
Tapered clutch
Outer shaft
CP6M3005
Part 3 Chapter 1 Cleaning
Edition 1.1 3-1-6 CP-6-series Mechanical Reference

1.8 Control Box Air Filter Cleaning (Every Month)
Point
If the air filter is clogged the effectiveness of the cooling fan will be reduced, and the
temperature in the control box will rise. If the machine is operated in this condition there
is a danger that the servo amplifiers and VME board will not function correctly.
In order to prevent clogging, clean off dust and dirt every month.
Part 3 Chapter 1 Cleaning
Edition 1.1 3-1-7 CP-6-series Mechanical Reference