DECAN_S1_Maintenance_EN.pdf - 第32页

DE CAN S 1 Mai nte nan ce H an dbo ok 3-3 chapt er 3 Daily Inspe ction Nex t Generation, Multi- Funct ional Placer Checking and cleaning the nozzle Caution Wipe the cleaning liquid on the nozzle using a clean cloth, ensu…

100%1 / 80
DECAN S1 Maintenance Handbook
3-2
chapter 3
Daily Inspection
Next Generation, Multi-Functional Placer
Checking and cleaning the nozzle
Daily Inspection
Step 6.
Insert the nozzles in the hole.
Nozzle Insertion hole
Nozzle net
Step 7.
Clean the nozzles with the ultrasonic cleaner and inject
air into the nozzle holes using an air gun.
Air gun
Nozzle
hole
Pneumatic air
spraying direction
Caution
Using the air gun without putting on goggles may cause injury to
the eyes of the operator. Be sure to wear goggles when using the
air gun.
Step 8.
When foreign materials (solder paste, etc.) remain inside
the nozzle, pass a pin through the nozzle hole and clean
it with an air gun.
Residual foreign material
(solder paste, etc.)
Inner bore
penetrating pin
Pin insert
direction
Air gun
Pneumatic
air spraying
direction
If the foreign materials (solder paste, etc.) have not been removed, repeat
cleaning once more.
DECAN S1 Maintenance Handbook
3-3
chapter 3
Daily Inspection
Next Generation, Multi-Functional Placer
Checking and cleaning the nozzle
Caution
Wipe the cleaning liquid on the nozzle using a clean cloth, ensuring
none remains on the nozzle.
When foreign materials remain on the nozzle continuously, contact
our C/S company (STS) or local agent to solve the problem.
Use the ultrasonic cleaning machine, the clean case the Nozzle, you
will be able to improve the cleaning of the nozzle.
Step 9.
The method to clean the nozzle is as follows:
Spray the cleaning liquid recommended by us on the nozzle exterior using a spray
straw.
Clean the nozzle exterior with a clean cloth within 1 minute after spraying the
cleaning liquid.
If the foreign materials (solder paste, etc.) have not been removed, repeat
cleaning once more.
Step 10.
If lubrication of the nozzle spring is insufficient due to
its having become thick, inject a suitable amount of the
nozzle lubricating oil provided with the machine.
lubricant for nozzle
Lubricating Point
Step 11.
Press the nozzle 4~5 times after lubricating so that the
ubricating oil is uniformly spread out.
Nozzle spring
DECAN S1 Maintenance Handbook
3-4
chapter 3
Daily Inspection
Next Generation, Multi-Functional Placer
Checking and cleaning the nozzle
Daily Inspection
Caution
Use only the required amount of lubricating oil. If insufficient
lubricating oil is applied, the nozzle will not operate smoothly.
If too much lubricating oil is applied, it may lump together with
foreign materials causing defective pickup.
Step 12.
Release the emergency stop as described in "Releasing
'Emergency Stop' mode" on page 1-6 and perform the
operation again.