DECAN_S1_Maintenance_EN.pdf - 第57页

Mon thly Inspe ction chapt er 5 Nex t Generation, Multi- Funct ional Placer DE CAN S 1 Mai nte nan ce H an dbo ok 5-4 Checking and Cleaning Right Cover Cooling F an Monthly Inspe ction Checking and Cleaning Right Cover C…

100%1 / 80
Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-3
Checking and Cleaning Conveyor Sensor / Fiducial Mark
Checking and Cleaning Conveyor Sensor / Fiducial
Mark
Tool for Maintenance
Cleaning liquid, clean cloth
Measures
Step 1.
Move the X Frame to rear by referring to "Backward
movement of the X-frame" on page 1-4
Step 2.
Press the 'STOP' and 'RESET' buttons in order after
pressing the 'EMG' button on the OP panel to stop
operation.
For more details, refer to "How to perform emergency stop" on page
1-2.
Step 3.
Check the recognition accuracy of the corresponding
photo sensor as shown in the following figure. (The red
LED is turned on when an object is recognized.)
Rear
Front
Step 4.
Clean the sensor window and fiducial mark with a swab
and an ultra-fine fiber cloth.
①Remove the dust or foreign material on the sensor window using the cotton
swab
②Remove the dust or foreign material on the sensor window using the clean
cloth
(Time required: 10min / No. M-2)
Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-4
Checking and Cleaning Right Cover Cooling Fan
Monthly Inspection
Checking and Cleaning Right Cover Cooling Fan
Tool for Maintenance
Vacuum cleaner, screwdriver(+)
Measures
Step 1.
Turn off the power supply to the machine as described
ino "How to turn off the power supply" on page 1-1.
Step 2.
Remove the cover on the left and right side of the
machine using a crosshead screwdriver.
If there is not enough space for fan removal since the machine is
configured in line with a machine by its side, clean the filter and fan
using an air gun without removing them.
Step 3.
Clean the cooling fans using a vacuum cleaner.
Step 4.
Turn on the main switch after cleaning to check the
noise and movement of the cooling fan.
If abnormal noise and operational problem still occur, turn off the
main switch again and replace the cooling fan.
Caution
When the main switch is turned on, since the cooling fan operates,
user's hand may get injured. Careless touching of the cable, etc.
may cause electric shock. Therefore, special care is need.
Caution
The cooling fan replaement work accomanies a danger.
Therefore, contact out C/S company (STS) or local agent.
(Time required: 10min / No. M-3)
Monthly Inspection
chapter 5
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
5-5
Checking and Cleaning the cooling fan of the front and rear covers
Checking and Cleaning the cooling fan of the front
and rear covers
Tool for Maintenance
Vacuum cleaner, screwdriver(+)
Measures
Step 1.
Turn off the power supply to the machine as described
ino "How to turn off the power supply" on page 1-1.
Step 2.
Remove the cover on right side of the machine using a
crosshead screwdriver.
Step 3.
Clean the cooling fans using a vacuum cleaner.
Step 4.
Turn on the main switch after cleaning to check the
noise and movement of the cooling fan.
If abnormal noise and operational problem still occur, turn off the
main switch again and replace the cooling fan.
Caution
When the main switch is turned on, since the cooling fan operates,
user's hand may get injured. Careless touching of the cable, etc.
may cause electric shock. Therefore, special care is need.
Caution
The cooling fan replaement work accomanies a danger.
Therefore, contact out C/S company (STS) or local agent.
(Time required: 15min / No. M-4)