Consumable Parts List
chapter 6
Appendix
No PART NAME PART No. MODULE Replacement cycle REMARK
1 CABLE ASSY-CABLE ASSY-LR_ZR_DRV_FAN AM03-006409A Y CABLE DUCT Check it at three years intervals
2 FILTER-ELEMENT [PF3-24-005-01] HP04-000103A AIR Check it at three years intervals
Checking and replacing the air filter
(page 3-10)
3 FILTER,OIL-ELEMENT[PFH3000-005A-6081] HP04-001045A Mist Separator Check it at three years intervals
Checking and replacing the mist
separator filter (page 3-12)
4 PUMP-KHF-14-V-01 HP11-000193 AIR Check it at six month intervals
5 FAN_CABLE_ASSY SM-FAN00 J90833316A AIR Check it at three years intervals
6 HARNESS-V1+ LOOF FAN CABLE ASSY EP02-001745B COVER Check it at three years intervals
7 FAN_CABLE_ASSY SM-FAN00 J90833316A ELECTRIC DEVICE Check it at three years intervals
8 FUSE[250V 5A] EP10-900438 ELECTRIC DEVICE Replace when a failure occurs to it
9 FUSE[250V 10A] EP10-900439 ELECTRIC DEVICE Replace when a failure occurs to it
10 BELT_WIDTH_SYNC 025-XL-286AJ MC05-900056 CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
48.
Consumable Parts List
Appendix
chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Maintenance Handbook
6-2
Consumable Parts List
Appendix
No PART NAME PART No. MODULE Replacement cycle REMARK
11 TIMMING_BELT_WIDTH 180-3GT-9 MC05-900058 CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
48.
12 BELT_WORK MAM-5P-1550-6W MC05-900057 CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
48.
13 TIMING BELT-TIMING-BELT-1491-3GT-20;3GT MC05-000151 CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
35.
14 BELT-SHUTTLE_MAM;FLAT,945,6W,1.2MM MC05-000068A CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
35.
15 BELT-MAM-5P-1504-6W;FLAT,1504,6,1.2 MC05-000234 CONVEYOR
Check the belt at 6 month
intervals and replace it if it has
any problems.
Technical Reference Refer to Page
36.
16 STEEL BALL [DIA2, SUS304] J7055140A HEAD Check it once per year
17 SILICON TUBE(BLACK) J72550021C HEAD Check it once per year
18 SUCTION_FILTER VYF44-M-50M HP04-900036 HEAD Check it at three month intervals.
Checking and replacing the head