00197195-02-UG SetupCenter 5.1_en - 第119页
Working with the Setup Center Application Splice Monitoring Splice Mo nitor User Guide SIPLACE Setup Center 5.1 11 9 7.5.1.2 Correcting Splice Errors with the PDA Scanner Confirm the following question which appears: CAU…

Working with the Setup Center Application
Splice Monitor Splice Monitoring
118 User Guide SIPLACE Setup Center 5.1
7.5.1.1 Correcting Splice Errors with the Setup Center GUI
Step-by-Step Procedure
Step 2:
Confirm the following question which appears:
Step 3:
► If the Activate pickup position with verification function has been activated, it is necessary to scan
the barcode with the barcode fragment "Component" or "UID" in order to activate the track, otherwise
the track will automatically be deactivated.
The component level on the packaging unit has now been matched with the data in Setup Center.
Step 1:
► Open the context menu with a right mouse-click and
start the Fix missing splice …function.
Icon Action Meaning
1Yes - the splice point has al-
ready passed the pickup posi-
tion.
Rejects the current packaging unit (packaging unit will no
longer be recorded), the quantity of the following packaging
unit remains the same and all information is sent to the sta-
tion.
2No - the splice point has not yet
reached the pickup point.
Sets the quantity of the current packaging unit to the thresh-
old value (for example: 1% of 1000 = 10 components), the
quantity of the following packaging unit is set to the original
quantity and all information is sent to the station.

Working with the Setup Center Application
Splice Monitoring Splice Monitor
User Guide SIPLACE Setup Center 5.1 119
7.5.1.2 Correcting Splice Errors with the PDA Scanner
Confirm the following question which appears:
CAUTION
If the user activates this track at the station, without consulting the Setup Center, this track will
be deactivated again at the next component level update.
Step 1
► Scan the refill barcode.
Step 2
► Scan in the Track barcode of the packaging unit.

Working with the Setup Center Application
Splice Monitor Plausibility Check - Missing Refill
120 User Guide SIPLACE Setup Center 5.1
7.5.2 Plausibility Check - Missing Refill
If a splice point is expected for a track and the set overshoot value is reached, this track is deactivated
at the station and displayed in red with an error symbol in Setup Center. Detailed information will be
shown in the notifications window.
Icon Action Meaning
1Yes - the splice point has al-
ready passed the pickup posi-
tion.
Rejects the current packaging unit (packaging unit will no
longer be recorded), the quantity of the following packaging
unit remains the same and all information is sent to the sta-
tion.
2No - the splice point has not yet
reached the pickup point.
Sets the quantity of the current packaging unit to the thresh-
old value (for example: 1% of 1000 = 10 components), the
quantity of the following packaging unit is set to the original
quantity and all information is sent to the station.
Step 3:
► If the Activate pickup position with verification func-
tion has been activated, it is necessary to scan the
barcode with the barcode fragment "Component" or
"UID" in order to activate the track, otherwise the
track will automatically be deactivated.
The component level on the packaging unit has now been
matched with the data in Setup Center.
CAUTION
If the user activates this track at the station, without consulting the Setup Center, this track will
be deactivated again at the next component level update.