00197195-02-UG SetupCenter 5.1_en - 第51页
Setting System Components Component Level Indicator Station Software Settings (from Version 60x) User Guide SIPLACE Setup Center 5.1 51 Key to i cons 1. At least one track is being m onitored by the component level indic…

Setting System Components
Station Software Settings (from Version 60x) Component Level Indicator
50 User Guide SIPLACE Setup Center 5.1
4.1.2 Component Level Indicator
With the setup verification data, SIPLACE Setup Center can supply the original packaging unit size
(component quantity) for the component level indicator. Then throughout the entire placement process
the component level indicator shows when individual feeders are running empty and need to be refilled.
When the threshold values in the component level indicator are activated, a warning is given to indicate
that a track is going to run empty. If the operator reacts promptly to this warning, the machine can be
prevented from coming to a standstill as a result of a "Track empty" error.
In the main view of the station you can see whether the system is working with the component level in-
dicator or not. Configuration is performed during release and is displayed in the "Component Level Indi-
cator" view at the station.
NOTICE
Activating forced setup verification
After a new installation of the station software, forced verification will always be disabled.
Please activate it manually.
WARNING
Only disable the setup verification at the station computer in emergencies
If you want to disable the setup verification, always do this in SIPLACE Pro. The setting in the
station software may only be used in absolute emergencies, as the station software, SIPLACE
Pro and Setup Center systems will then no longer be synchronized.
NOTICE
Defining the forced setup verifications settings
There are currently no technical means for SIPLACE Setup Center to determine whether forced
setup verification for the machine is enabled or disabled.
For this reason it is always necessary to ensure manually that the settings for setup verification
are the same at the station and in Setup Center!

Setting System Components
Component Level Indicator Station Software Settings (from Version 60x)
User Guide SIPLACE Setup Center 5.1 51
Key to icons
1. At least one track is being monitored by the component level indicator and the level of all tracks is
below the warning threshold.
2. For at least one track being monitored by the component level indicator, a warning has been issued
and the track in question is highlighted in yellow in the component level indicator view. The preset
threshold value was undercut.
3. For at least one track that is being monitored by the component level indicator, an error message
has been issued; the track in question is disabled and highlighted in red in the component level in-
dicator view. The preset threshold value was undercut. After refilling, the track needs to be reactivat-
ed.
4.1.2.1 Component Level Indicator Menu
From the main menu at the station, you can select the Feeders button to access the component level
indicator menu. The figure below shows the component level indicator menu of the station software 50x.
1
2
3

Setting System Components
Station Software Settings (from Version 60x) Component Level Indicator
52 User Guide SIPLACE Setup Center 5.1
1. Component level indicator view of all verified packaging units.
2. Configuration of the view.
3. Information and editing of the component level of a selected packaging unit.
4. Component level indicator switch
5. Activates/ deactivates the component level and configures the threshold values.
Component Level Indicator View
The view provides information about component levels and the status of all verified packaging units.
1
2 3 4