00197195-02-UG SetupCenter 5.1_en - 第69页
Setting System Components Component Level Indicator Station Software Settings (from Version 70x) User Guide SIPLACE Setup Center 5.1 69 Waffle pack tray at position x ▪ Name of the component ▪ Component shape name – Clic…

Setting System Components
Station Software Settings (from Version 70x) Component Level Indicator
68 User Guide SIPLACE Setup Center 5.1
4.2.2.3 Matrix Tray Changer (MTC)
► Select the Setup button (1).
► Select the button with the location (2) on which the MTC is present.
Setup – MTC
Use the icon to switch between views.
Refill position
▪ Move to refill position
– This moves to the position in which the waffle pack tray carriers for all levels can be replaced.
Components can no longer be picked up from the WPC.
▪ End refill mode
– Moves the complete WPC back to working position. Components can be picked up again.
▪ Check WPT occupation
– This compares the existing waffle pack trays with those defined in the setup.
– The position of the waffle pack tray (cassette, level) is then shown. If waffle pack tray carriers,
which should be present according to the setup, are missing, this will also be shown.
Prepare level
The lifting axis moves the selected level to the feed axis position and the waffle pack tray carrier will be
moved to the staging position.
Confirming waffle pack tray changeover
The waffle pack tray carrier is filled according to the target setup and is inserted into the relevant level.
The maximum number of components is entered as the current component level and the waffle pack
trays are taken back into operation.
Error list (is only shown if an error occurs)
Brief description of errors for the waffle pack tray affected.

Setting System Components
Component Level Indicator Station Software Settings (from Version 70x)
User Guide SIPLACE Setup Center 5.1 69
Waffle pack tray at position x
▪ Name of the component
▪ Component shape name
– Click on this button to open a dialog box in which all known information about the component is
shown.
▪ The complete Component Name plus the Component Shape Name will be shown with the corre-
sponding description (customized comment text stored in SIPLACE Pro).
Activate
Puts the waffle pack tray back into operation.
A waffle pack tray is automatically disabled if its description and the prescribed text in SIPLACE Pro do
not match.
As long as a waffle pack tray is disabled, its component level position can not be changed/corrected.
Set full
Confirms that the waffle pack tray has been filled with components.
Set empty
Confirms that the waffle pack tray has been emptied.
Change filling level...
Sets the number of components in the waffle pack tray
First mark the component up to which the waffle pack tray is filled, in the waffle pack tray diagram and
then select OK.
Position Correction (can only be enabled from operator level "Service").
▪ Position correction...
– Starts a dialog box for manual correction of the component pickup position.
– The table shows the deviation to the relevant prescribed value.
▪ Reset Correction
– Resets the pickup position to the prescribed value in the setup.
► Use the icon to switch over to the table view.

Setting System Components
Settings in the SIPLACE Pro Programming System Barcode Option in the Stations Editor
70 User Guide SIPLACE Setup Center 5.1
MTC - setup (table view)
4.3 Settings in the SIPLACE Pro Programming System
For setup verification and component level indication in SIPLACE Setup Center, the following must be
configured in SIPLACE Pro (for detailed Information about the settings, please see the operating instruc-
tions for SIPLACE Pro additionally).
4.3.1 Barcode Option in the Stations Editor
To operate Setup Center, enable the setting "Component Barcode". Make sure
that the barcode reader is parameterized in the programming system.
► Select the stations in the Station tree view.
► Go to Options and enable "Component Barcode".