NR_WPW_WPC_F3_F4 - 第26页
SIEMENS AG 19 96 All righ ts reserve d Technis che Änderunge n vorbeha lten Arti kel-Nr. : xxxxx xxx-x x Siem ens Ak tienge sellsc haft Bestellun g an: SIEMENS L&A, Elec troni cs Asse mbly Rupert-Mayer-Stra sse 44 D-…

WPW an SIPLACE 80 F3/F4 / WPC on SIPLACE 80 F3/F4 Nachrüstanleitung/Retrofitting Instructions
Ausgabe 09/96 / 09/96 Edition
Seite/Page 12 von/of 12
•
Save the configuration file.
•
Switch to the data manager and translate the configuration file .
•
Check the error message file
•
Start the consistency check for all setups already present.
•
Check the consistency check error message files
•
Use the UNIX line computer operating instructions in order to create the individual wafflepack
magazines for the wafflepack changer.
3RVVLEOHHUURUV
−
Wafflepack changer fiducial not found
⇒
Wafflepack changer not aligned correctly
(field of view of PCB camera).
−
Component not picked up
⇒
Wrong X or Y coordinates of wafflepack magazine
−
Pick-up position too high/low
⇒
Wrong Z position of wafflepack magazine