5 Working with the machine 5.2 Switching on/off the ASM ProcessLens Dual-lane Instruction Guide ASM ProcessLens Dual-lane 06/2018 77 5.2 Switching on/off the ASM ProcessLens Dual-lane NOTICE Operator Manual ASM ProcessLe…

5 Working with the machine
5.1 Controls and displays
76 Instruction Guide ASM ProcessLens Dual-lane 06/2018
Main power switch in ON position
(see fig. "Controls and displays" [}74])
After switching on the main power switch, 24 V DC and 240 V AC are present.
Main power switch in OFF position
(see fig. "Controls and displays" [}74])
The main power switch disconnects the single phase from the power supply.
DANGER
Death, serious injury or considerable damage may result if these machines are
handled incorrectly
► Always follow the applicable accident prevention and safety regulations (particularly
DIN EN 60204, part 1 or IEC 60204, part 1) and the safety regulations in your own
country.
► The safety door to the power supply must ONLY be opened by appropriately qualified
and trained personnel.
Machine idle lamp
(see fig. "Controls and displays" [}74])
On: The main power switch is switched to ON position. Power is supplied to the power distribution
module.
Off: The input voltage is not present.
Start button, green
(see fig. "Controls and displays" [}74])
After switching on the main power switch and having started the inspection software press the start
button to set ASM ProcessLens Dual-lane into regular inspection mode. Do the same if the EMER-
GENCY STOP had been engaged and is now released or if the protective hood had been opened
and is now closed.
Stop button, black
(see fig. "Controls and displays" [}74])
This button is used to stop the machine and will perform the following tasks:
●
Stop the production operations and puts the machine in idle mode.
●
The control power is still present.
The EMERGENCY STOP button is red and latches in the ON position when pressed. When you
press the EMERGENCY STOP button, the switching contact of safety interlock module opens.
The signaling contact of the EMERGENCY STOP button opens.
The inspection cycle is interrupted and can then either be continued or cancelled once the machine
is working correctly again.
NOTICE
ASM ProcessLens Dual-lane electrical diagrams
For details, please refer to the ASM ProcessLens Dual-lane electrical diagrams.
Release the EMERGENCY STOP button
●
Release the EMERGENCY STOP button from latched position after being activated.
●
Operator can press the START button, to resume production operation.
●
The software sequence for START button as follows:
– Software will check that the hood is closed and EMS is not activated.
– Software will lock the door and reset the safety relay.
– Software will check that the safety relay interlock is cleared and enable the motors.
See also
2 5.1.1 "Overview" [}74]

5 Working with the machine
5.2 Switching on/off the ASM ProcessLens Dual-lane
Instruction Guide ASM ProcessLens Dual-lane 06/2018 77
5.2 Switching on/off the ASM ProcessLens Dual-lane
NOTICE
Operator Manual ASM ProcessLens
For a detailed description, please refer to the Operator Manual ASM ProcessLens [Item
No.: 00900067-xx]
To switch on the ASM ProcessLens Dual-lanemachine, proceed as follows:
► Check whether the stations are connected to the power supply.
► Perform a visual check of the stations.
► Make sure that there are no obstacles in the travel range of the inspection head assembly.
► Make sure that the conveyor is free of any PCB.
► Switch the station on at the main power switch.
To switch off the ASM ProcessLens Dual-lane machine, proceed as follows:
► End all inspection procedures.
► Make sure there are no boards inside the ASM ProcessLens Dual-lane.

5 Working with the machine
5.2 Switching on/off the ASM ProcessLens Dual-lane
78 Instruction Guide ASM ProcessLens Dual-lane 06/2018