2.7.10 Calibrate all heads and cameras:
: Calibrate the P&P Head, camera and nozzle changer.
: Carry out the head mapping, if necessary.
2
: Back-up the machine data.
2
: Restart again.
This completes the conversion. 2
2.7.11 Dismounting the P&P module
A standard D1 machine is converted into a D1 single head (with C&P placement head).) 2
The second placement head on the gantry is dismounted with
its nozzle changer and stationary
cameras and deactivated at SIPLACE Pro and SITEST. In detail the work is described above in
chapter "Mounting". 2
2
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
73
2.8 Installing the Collect&Place placement head
2.8.1 Configuring the C&P head using the machine configuration wizard
: Start SITEST and select "Settings—Machine Configuration".
: Enter in the machine configuration the new placement head, cameras (standard camera type
28 / optional FC camera type 29) and nozzle changer.
Save the result!
: Shut down the station computer and switch off the placement machine.
2Detailed instructions for configuring the placement head can be found in the SITEST online help
under Settings / Settings for the Twin Head. 2