00195427-02_AI_HeadReconfigKitsD1D2_DE EN - 第85页

Assembly instructions Head Re configuration SIPLACE D 1 / D2 Edition 03/2007 83 2.8.7 Final mechanical work This mechanical work mu st be completed prior to Firmware download (C hapters 1.7.9 and 1.8.8), ( Chapter 2.7.9 …

100%1 / 94
X22
X12X10
X13
X14
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
82
2
Fig. 2.8.9 Plug in two cables
2
: Fix the 4 cables with the strain relief.
2
2.8.6 Replacing the servo cards
2
Wear an ESD armband for the whole time you are working on the placement head and servos! 2
2
: Use the machine key to open the door of the servo unit.
2
Place the axis and servo cards in accordance with your machine configuration.
See the diagram in the annex (Chapter 2.9.1). 2
2
2
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
83
2.8.7 Final mechanical work
This mechanical work must be completed prior to Firmware download (Chapters 1.7.9 and 1.8.8),
(Chapter 2.7.9 and Chapter 2.8.8) otherwise calibration of the nozzle changer will not be
poss
ible. 2
2
: Mount the waste chute and fix in place.
: Mount the nozzle changer and screw tight (2 screws M6x12).
: Fit the waste bin holder (2 screws M6x14).
: Insert the new reject bin.
: Doc the component table or position the tape container and dock the WPC4.
2
2.8.8 Firmware download
2
Shown in this chapter is the menu of the HF-series. In principle, this is comparable with the D-
series. 2
The mechanical work must be completed prior to the Firmware download, otherwise calibration
of the pipette changer will not be possible. 2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
84
: Download the C&P Head firmware.
Fig. 2.8.10 Firmware download as example HF (D-series similar)
2From SW version 604 upwards the download is not restricted to SIPLACE-Service anymore. 2