Assembly instructions Head Re configuration SIPLACE D 1 / D2 Edition 03/2007 85 2 2

Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
84
: Download the C&P Head firmware.
Fig. 2.8.10 Firmware download as example HF (D-series similar)
2From SW version 604 upwards the download is not restricted to SIPLACE-Service anymore. 2

Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
85
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
86
2.8.9 Calibrate all placement heads and cameras
: Calibrate all placement heads, cameras and nozzle changers.
: Perform RV head mapping if necessary.
2
: Back-up the machine data.
2
: Restart again.
This completes the conversion. 2
2
2.8.10 Dismantling of C&P head
By dismantling the C&P head, a SIPLACE D1 becomes a D1 single head (With P&P head). 2
Additional to the conversion work described above (chapter
"Mounting") both placement heads
must be reconfigured in SIPLACE Pro and SITEST. 2
– The C&P head, it’s component camera and nozzle changer must be deleted.
– In SITEST the P&P head with its nozzle changer
must be configured as "Head 1",
that means,
that also the nozzle changer in the SW 603 has to be reconfigured, although it is not changed
mechanically.
– Change thereby the pick up angle in all magazines from 18400 to 400.