Assembly instructions Head Reconfiguration SIPLACE D1 / D2 Edition 03/2007 86 2.8.9 Calibrate all placement heads and cameras : Calibrate all placement heads, camer as and nozzle changers. : Perform RV he ad mapping if n…

Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
85
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
86
2.8.9 Calibrate all placement heads and cameras
: Calibrate all placement heads, cameras and nozzle changers.
: Perform RV head mapping if necessary.
2
: Back-up the machine data.
2
: Restart again.
This completes the conversion. 2
2
2.8.10 Dismantling of C&P head
By dismantling the C&P head, a SIPLACE D1 becomes a D1 single head (With P&P head). 2
Additional to the conversion work described above (chapter
"Mounting") both placement heads
must be reconfigured in SIPLACE Pro and SITEST. 2
– The C&P head, it’s component camera and nozzle changer must be deleted.
– In SITEST the P&P head with its nozzle changer
must be configured as "Head 1",
that means,
that also the nozzle changer in the SW 603 has to be reconfigured, although it is not changed
mechanically.
– Change thereby the pick up angle in all magazines from 18400 to 400.

Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
87
2.8.10.1 Fan position for X motor ventilator
Both fans of D1 are positioned to cool the X motor of the C&P head at the pick up process. 2
Fan
Mount fan to this position
Filter mat
: Dismantle the cover on top of the placement system.
: Mount the fan for the cooling of the X motor to the left position seen from the PCB input side
(4 screws).
2
2
2
2