4-3 Tg1576-ID-SO Specied lubrication tools (1) Syringe This syringe can be used for two kinds of greases. Use the syringes and the nozzles properly . T wo Kinds of Greases : DAPHNE EPONEX GREASE No. 1 MOL YNOC GREASE AP…

4-2
Tg1576-ID-SO
1.2.2 Preparation for Lubrication
Prepare for the specied types of grease and lubrication tools.
Specied Greases
•
DAPHNE EPONEX GREASE No. 1 (IDEMITSU KOSAN)
Note
Before lubrication, wipe off old grease. Otherwise, the effect of grease and
oil will decrease.
Same Types of Lubricants
•
Grease T
ypes equivalent to DAPHNE EPONEX GREASE No. 1
(IDEMITSU KOSAN)
Table D1
Grease Names Makers
Alvania Grease No. 1 Showa Shell Sekiyu K.K
Multinoc Grease 1 NIPPON OIL CORPORATION
Jomo Lisonix Grease No. 1 JAPAN ENERGY CORPORATION
Dynamax No. 1 COSMO OIL LUBRICANTS CO., LTD.
Lithtan 1 ESSO OIL
MP Grease 1 KYGNUS
Gemico MP-1 TonenGeneral Sekiyu K.K
Multemp PS1 KYODOH YUSHI CO., LTD.
•
Grease Types equivalent to MOLYNOC GREASE AP1
(NIPPON OIL CORPORA
TION)
1.2 Preparation for Maintenance
0707-001

4-3
Tg1576-ID-SO
Specied lubrication tools
(1) Syringe
This syringe can be used for two kinds of greases.
Use the syringes and the nozzles properly.
Two Kinds of Greases
: DAPHNE EPONEX GREASE No. 1
MOLYNOC GREASE AP1
Appearance
1
2
3
4
5
6
7
8
9
10
12
mL
SINGLE USE ONLY
Fig. D1
Table D1
1.2 Preparation for Maintenance
0707-001

4-4
Tg1576-ID-SO
2. Inspection, Cleaning, and Lubrication Spots
2.1 Traverse
CAUTION
When the single-transfer tray feeder is set to or removed from
the cart, or the tray feeder itself is moved, two persons should
hold the specied handle and take the greatest care not to drop it
onto anybody's foot.
When the cover is to be opened or closed, open or close it slowly
with the handle held securely.
Take care so that your nger is not caught.
Linear Guides
Take ample care not to leave any
waste threads after cleaning.
No.18
Required Time: 5 minutes
Linear Guides
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
(1) Remove the two screws on the transparent
cover.
(2) Wipe old grease using a oil cloth and apply
new grease in the groove on the linear guide
using a syringe.
Take ample care not to leave any
waste threads after cleaning.
Use No. 18 (green) nozzle.
No.18
Required Time: 10 minutes
Screws (2 Places)
Note
Notice
Note
Notice
Use No. 18 (green) nozzle.
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Wipe old grease using a oil cloth and apply
new grease in the groove on the linear guide
using a syringe.
Fig. D2
0709-002