00192471-03 - 第174页
5 Station extensions User Manual S IPLACE HS-50 5.9 Vacuum t ooling Soft ware V ersion SR.50x.xx 01/2006 US E dition 174
User Manual SIPLACE HS-50 5 Station extensions
Software Version SR.50x.xx 01/2006 US Edition 5.9 Vacuum tooling
173
5.9 Vacuum tooling
Vacuum tooling is another module that is used to increase the placement accuracy for concave
PCBs. The vacuum surface of this device picks up concave PCBs during processing and aligns
them so they are flat. 5
The vacuum tooling module can be used on both single and dual conveyors, and is fitted to the
lifting tables. 5
5.9.1 Description of the functions
The PCB is fed to the processing belt, where it is stopped. The lifting table moves up and the vac-
uum circuit for the vacuum tooling device is opened. The PCB is then held in place by the vacuum
tooling device, which is pressed with a spring action against the PCB by the lifting table. This
causes the suction cups of the tooling device to press against the PCB and hold it firmly in posi-
tion. 5
The vacuum channels are vented after placement. The lifting table is lowered, the PCB is re-
leased, and can then be moved on. 5
5
5 Station extensions User Manual SIPLACE HS-50
5.9 Vacuum tooling Software Version SR.50x.xx 01/2006 US Edition
174

User Manual SIPLACE HS-50 Index
01/2006 US Edition
175
Index
12 mm S feeder for capacitors based
on powdered metal, model C/D
. . . . . . . . .123
12 mm S feeder for capacitors based
on powdered metal, model E
. . . . . . . . . . .124
12/16 mm S feeder
. . . . . . . . . . . . . . . . . . . . . .122
12-segment collect&place head
. . . . . . . . . 16, 18
angular accuracy
. . . . . . . . . . . . . . . . . 18, 38
component specification
. . . . . . . . . . . . . . . .38
component vision module
. . . . . . . . . . . . . . .37
description
. . . . . . . . . . . . . . . . . . . . . . . . . .38
max. placement rate
. . . . . . . . . . . . . . . . . . .38
maximum stroke of the Z axis
. . . . . . . . . . .38
motor for "Reject" valve
adjustment drive
. . . . . . . . . . . . . . . . . . . . . .37
nozzle types
. . . . . . . . . . . . . . . . . . . . . . . . .38
overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . .37
placement accuracy
. . . . . . . . . . . . . . . 18, 38
programmable set-down force
. . . . . . . . . . .38
range of components
. . . . . . . . . . . . . . . . . .38
star motor
. . . . . . . . . . . . . . . . . . . . . . . . . . .37
star with 12 sleeves
. . . . . . . . . . . . . . . . . . .37
structure
. . . . . . . . . . . . . . . . . . . . . . . . . . . .37
technical data
. . . . . . . . . . . . . . . . . . . . . . . .38
turning station
. . . . . . . . . . . . . . . . . . . . . . . .37
Z-axis drive
. . . . . . . . . . . . . . . . . . . . . . . . . .37
24/32 mm S feeder
. . . . . . . . . . . . . . . . . . . . . .125
3 x 8 mm S feeder
. . . . . . . . . . . . . . . . . . . . . .120
3 x 8 mm S feeder for 0201/0402
components
. . . . . . . . . . . . . . . . . . . . . . . .121
8 mm S II feeder
. . . . . . . . . . . . . . . . . . . . . . . .119
A
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Activating the ’PCB data transfer’ option
. . . . .168
Adequately trained
. . . . . . . . . . . . . . . . . . . . . . .45
Admissible load per unit area on foundation
. . . .23
Affected employees
. . . . . . . . . . . . . . . . . . . . . .91
Ambient temperature
. . . . . . . . . . . . . . . . . . . . .22
Atmospheric humidity
. . . . . . . . . . . . . . . . . . . . .22
Authorized accessories
. . . . . . . . . . . . . . . . . . . .48
Authorized employees
. . . . . . . . . . . . . . . . . . . 91
B
Bulk case feeder . . . . . . . . . . . . . . . . . . . . . . . 127
C
C&P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
C&P12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CAUTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Center of gravity
. . . . . . . . . . . . . . . . . . . . . . . . 24
Centering fiducial offset
. . . . . . . . . . . . . . . . . 170
Ceramic substrate centering
. . . . . . . . . . . . . . 160
centering types
. . . . . . . . . . . . . . . . . . . . . 160
compressed air connection
. . . . . . . . . . . . 162
connecting nozzle
. . . . . . . . . . . . . . . . . . . 161
fiducial criteria
. . . . . . . . . . . . . . . . . . . . . . 162
fiducial shape
. . . . . . . . . . . . . . . . . . . . . . 164
fiducial structure
. . . . . . . . . . . . . . . . . . . . 165
general
. . . . . . . . . . . . . . . . . . . . . . . . . . . 160
maintenance
. . . . . . . . . . . . . . . . . . . . . . . 161
mechanical centering
. . . . . . . . . . . . . . . . 160
normal lighting
. . . . . . . . . . . . . . . . . . . . . 160
oblique lighting
. . . . . . . . . . . . . . . . . . . . . 163
optical centering
. . . . . . . . . . . . . . . . . . . . 162
substrate format
. . . . . . . . . . . . . . . . . . . . 162
substrate model
. . . . . . . . . . . . . . . . . . . . 162
substrate thickness
. . . . . . . . . . . . . . . . . . 162
technical data
. . . . . . . . . . . . . . . . . . . . . . 162
transport type
. . . . . . . . . . . . . . . . . . . . . . 160
Change shift
. . . . . . . . . . . . . . . . . . . . . . . . . . 103
Changeover instructions
. . . . . . . . . . . . . . . . . 108
Changing feeder modules
. . . . . . . . . . . . . . . . 107
Changing jobs
. . . . . . . . . . . . . . . . . . . . . . . . . 102
Changing the component table
. . . . . . . . 108, 109
Changing the set-up
. . . . . . . . . . . . . . . . . . . . 107
Closing the protective covers,
safety instructions
. . . . . . . . . . . . . . . . . . . . 60
CO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Comp. coordinate system and pick-up angle
. 113
Component barcode
. . . . . . . . . . . . . . . . . . . . 146
compatible barcode types
. . . . . . . . . . . . . 149