D1 / D2 2 Assembly instructions for vacuum pump
11/2006 Edition
27
2 Assembly instructions
for vacuum pump
2.1 Safety instructions vacuum pump
Please refer to the additional instructions of the manufacturer of the vacuum pump concerning
safety, installation and setup (safety instructions of the placement machine see chapter 7.2). 2
2
2
2 Assembly instructions for vacuum pump D1 / D2
11/2006 Edition
28
2.2 Safety instructions
WARNING
Comply with the higher ranking "Safety Instructions" in Chapter "Operational Safety" in the User
Manual and Service Manual 2
The placement machines SIPLACE are powered by mains voltage.
Portions of the system are therefore conducting dangerous electricity, inside the machine even
wh
ile the master switch is turned off.
Death, serious injury or considerable damage may result
if these automatic placement systems
are handled incorrectly.
After you have properly carried out the
shut-down of the operating system:
Before all work the machine must be turned off at the main switch and isolated from the mains. In
additi
on, the compressed air supply must be turned off at the main valve of the compressed air
unit in the machine base and the compressed air lines must be bled by actuating the needle valve
at the compressed air unit.
Danger: For anyone wearing a heart pacemaker it is no
t permitted to work near linear motors, as
described in detail in the User Manual and the Service Manual, Chapter "Special Safety Instruc-
tions when working in vivinty of powerful magnetic fields" .
Obey the applicable accident prevention regulations, DIN standards and special safety codes of
your
country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base.
Follow the instructions regarding residual voltages in Chapter "Operational Safety".
Comply with regulations on ESDs (see
Chapter "Operational Safety").
During the work of retrofitting secure the machine conscientiously against other personnel and
pre
vent it from being turned back on without authorization, as described in the User Manual in the
chapter "Locking the Machine...".
There is additional, higher risk of accident when working with the SITEST program.
The SITEST program is only to be started by personnel who are authorized to do so. 2
2
2.2.1 Definitions
2
Caution 2
2
2
2
Note 2
D1 / D2 2 Assembly instructions for vacuum pump
11/2006 Edition
29
2.3 Necessary parts
Description Item no. 2
1 pc D1 Vacuum Pump Connection Kit 00119899-xx 2
consisting of: 2
1 pc DLM2 Vacuum generator for the vacuum pump 03012076-xx 2
1 pc D1/D2 Vacuum distributor 03053022-xx 2
1 pc Vacuum tube 03053080-xx 2
0,2 M Pneumatic tube TUS 0805 B Soft-PU 03005759-xx 2
1 pc T-Fitting QST-6 00320170-xx 2
12 M Siphon pipe- and pressure hose Di 32 HELISPRING 00368279-xx 2
1 pc Y-Fitting HELICONNECT 948 032 00368697-xx 2
6 pc Hose Clamp DIN 3017 NW 32 - 50 00363127-xx 2
1 pc Release tool for Q8 03047090-xx 2
1 pc Release tool for QSC-10H 03051853-xx 2
2
1 pc Anschluss-Kit Vakuumpumpe D2 00119900-xx 2
consisting of: 2
2 pc DLM2 Vacuum generator for the vacuum pump 03012076-xx 2
1 pc D1/D2 Vacuum distributor 03053022-xx 2
12 M Siphon pipe- and pressure hose Di 32 HELISPRING 00368279-xx 2
1 pc Y-Fitting HELICONNECT 948 032 00368697-xx 2
6 pc Hose Clamp DIN 3017 NW 32 - 50 00363127-xx 2
1 pc Release tool for Q8 03047090-xx 2
1 pc Release tool for QSC-10H 03051853-xx 2
2
1 pc Vacuum pump 00119017-xx 2
2
2
The current list of spare parts can be found at www.siplace.com
After logging on, please click “Start” below “SIPLACE Parts Catalogue, easy search for SIPLACE
spare parts!” 2
2.4 Necessary tools and consumables required
Ballpoint Hex Wrench Kit
Cable Clips Kit
Wire Cutters
Tube Pliers
Pliers
Depending on the machine set-up the modifying should be finished in about 1 - 1.5 hours. 2