FCM_User Reference Manual.pdf.pdf - 第104页

MIS User Re ference Manual 4022 5 91 96082 5-12 F CM Mult ifl ex 02.02 fcm05 14a.tif SCREE N 5-7 [Prod uct ion e v ent s .. .] s cre en exa m ple, p ar t 2 ✱✱ De tailed I nfo rmatio n ▼ Dis played Info rmatio n The [P ro…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-11
MIS
5.3.2.3 [Reports] > [Production events...]
TABLE 5-3 Quick Reference
fcm0513a.tif
SCREEN 5-6 [Production events...] screen example, part 1
Actions select [Functions...] in the MIS pull-down menu
select [Reports]
select [Production events...]
Conditions supervisor access level
order active
Information FCM Multiflex machine identification and serial no.
MIS period name + start/stop date/time
action spec name
order name
report date/time
total number of auto retries
total number of manual retries
total number of picked SMDs
total number of placed SMDs
total number of not placed SMDs (skipped)
number of machine errors
number of boards that are good, suspect or skipped
Display Options -
MIS
User Reference Manual 4022 591 96082
5-12 FCM Multiflex 02.02
fcm0514a.tif
SCREEN 5-7 [Production events...] screen example, part 2
✱✱ Detailed Information
Displayed Information
The [Production events...] report gives a general overview of error levels of both the
SMD handling (process performance) and the machine hardware (machine
performance).
REMARK: As the major part of the information concerns the process, this report type
has been assigned to the Process Performance line within the MIS functions
selection tree..
All errors are given in both absolute and PPM levels (see below).
fcm0515a.tif
SCREEN 5-8
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-13
MIS
The process errors are divided into auto retries and manual retries (see below).
[ fcm0516a.tif ]
SCREEN 5-9
An auto retry is a retry without operator intervention (automatic); the
maximum allowed number of auto retries is determined in the action spec,
(see SCREEN 5-10).
A manual retry is a retry by operator intervention. After the FCM Multiflex has
reached the auto retry number limit, it stops, and manual retries may be done by
the operator then. Note that only those manual retries are taken into account for
the
[Production events...] report that were successful at first attempt.
fcm0517a.eps
SCREEN 5-10 Action spec setting of the maximum number of auto pick retries (refires)
FEEDER 1 1 T8-M/4 T 333-222-112 SOD-80
COMMENT index coordinates are relative to pipette origin
COMMENT indx/brd /refholex/refholey/board_x /board_y
INDEX 1 3 -75.500 294.250 -81.500 138.000
INDEX 1 4 74.500 294.250 68.500 138.000
INDEX 2 3 4.500 294.250 -1.500 138.000
COMMENT pick coordinates are relative to pipette origin
COMMENT fd/pk/psh/rfr/pick_x /pick_y /pick_phi/na/prf/arf/ale/ple
PICK 1 1 1 2 19.000 77.000 90.0 1 75 55 80 80
COMMENT: In case a deviating dump position is needed enter
COMMENT: DUMP position_x position_y
COMMENT mount coordinates are in board coordinates
in this example, the number of auto(matic)
pick retries (or
refires
) is set to 2
rfr = refires