FCM_User Reference Manual.pdf.pdf - 第110页
MIS User Re ference Manual 4022 5 91 96082 5-18 F CM Mult ifl ex 02.02 fcm0 520a / 0521 a.ti f SCREE N 5-1 5 [Proc ess r eport... ] , All modu les scr e en e xample Report text ex plan ati on, All modules option See s cr…

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-17
MIS
• An auto retry is a retry without operator intervention (automatic); the
maximum allowed number of auto retries is determined in the action spec,
see SCREEN 5-13.
• A manual retry is a retry by operator intervention. After the FCM Multiflex
has reached the auto retry number limit, it stops, and manual retries may be
done by the operator then. Note that only those manual retries are taken
into account for the
[Process report...] report that were successful at first
attempt.
fcm0517a.eps
SCREEN 5-14 Action spec setting of the maximum number of auto pick retries (refires)
FEEDER 1 1 T8-M/4 T 333-222-112 SOD-80
COMMENT index coordinates are relative to pipette origin
COMMENT indx/brd /refholex/refholey/board_x /board_y
INDEX 1 3 -75.500 294.250 -81.500 138.000
INDEX 1 4 74.500 294.250 68.500 138.000
INDEX 2 3 4.500 294.250 -1.500 138.000
COMMENT pick coordinates are relative to pipette origin
COMMENT fd/pk/psh/rfr/pick_x /pick_y /pick_phi/na/prf/arf/ale/ple
PICK 1 1 1 2 19.000 77.000 90.0 1 75 55 80 80
COMMENT: In case a deviating dump position is needed enter
COMMENT: DUMP position_x position_y
COMMENT mount coordinates are in board coordinates
in this example, the number of auto(matic)
pick retries (or
refires
) is set to 2
rfr = refires

MIS
User Reference Manual 4022 591 96082
5-18 FCM Multiflex 02.02
fcm0520a/0521a.tif
SCREEN 5-15 [Process report...], All modules screen example
Report text explanation, All modules option
See screen example SCREEN 5-15
Report text Explanation
Module number the numbers of the used placement modules
Picked total numbers of picked SMDs
Auto retry after pick total number of automatic pick retries per place-ment
module that occurred after SMD was missing
immediately after pick action
align total number of automatic pick retries per place-ment
module that occurred after SMD was miss-ing upon
starting the align action (WVM only)
misalign total number of automatic pick retries per place-ment
module that occurred after SMD could not properly be
aligned
scroll area

4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-19
MIS
TABLE 5-6
Manual pick error ■ FCM Multiflex stopped after having reached the
autoretry limit
■ total number of manual pick retries per
placement module after SMD was missing
immediately after pick action
missing before align
■ FCM Multiflex stopped after having reached the
auto retry limit
■ total number of manual pick retries per
placement module after SMD was missing
upon starting the align action (WVM only)
misalign
■ FCM Multiflex stopped after having reached the
auto retry limit
■ total number of manual pick retries per placement
module after SMD could not properly be aligned
missing after align
■ FCM Multiflex stopped immediately after the SMD
was lost after performing the alignment action
■ total number of manual pick retries per
placement module
retained after place
■ FCM Multiflex stopped immediately after the SMD
was still present on the nozzle after trying to place it on
the board
■ total number per placement module of
manual pick retries
not placed (skipped) total number per placement module of picked SMDs
that are not placed (dumped) as a result of selecting
[Skip action] or [Skip board] in the [Error Recovery]
dialogue
Misalign details
(= Automatic +
manual retries)
X-offset the measured X-offset exceeded the X-reject level as
specified in the SMD info file
Y-offset the measured Y-offset exceeded the Y-reject level as
specified in the SMD info file
Phi-offset the measured Phi-offset exceeded the Phi reject level
as specified in the SMD info file
Width the measured SMD width exceeded the width
(tolerance) as specified in the SMD info file
Length the measured SMD length exceeded the length
(tolerance) as specified in the SMD info file
Not measurable the laser align or vision system was not able to
measure the SMD that was picked up (LAS: a laser
error occurred during the align process; WVM: not all
sides of the SMD within the camera’s field of view)
Lead count the vision system detected that the number of leads
measured on the North/South and/or East/West side of
the SMD are not the same (WVM only)