4022 591 96082 User Re ference Manual 02.02 FCM Multiflex 5-21 MIS fcm0 523a / 0524 a.ti f SCREE N 5-1 7 [Proc ess r eport... ] , Specific placement m odule scr een e xample , part 2 a nd 3 Report text ex plan ati on, Sp…

100%1 / 306
MIS
User Reference Manual 4022 591 96082
5-20 FCM Multiflex 02.02
TABLE 5-7
fcm0522a.tif
SCREEN 5-16 [Process report...], Specific placement module screen example, part 1
Report text Explanation
Misalign details
(= Automatic +
manual retries)
(continued)
Lead pitch the vision system detected that the distance between
all individual leads on one (or more) side(s) of the com-
ponent is not within the required tolerance (WVM only)
Lead width the vision system detected that the SMDs lead width is
out of tolerance (WVM only; for asymmetric SMDs with
only one lead at one side, as lead pitch does not
exist in this case)
Coplanarity the vision system detected that not all individual leads
on one (or more) side(s) of the SMD are positioned in-
line (for instance, one or more leads are bent) (WVM
only)
Component geome-try the vision system detected that the leads on the North/
South and/or East/West side of the SMD are not
exactly opposite each other (for SMDs with leads on all
four sides only) (WVM only)
Time lost due to
errors
Response the time between error detection and error recovery
Repair the time between error recovery and production run
restart
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-21
MIS
fcm0523a/0524a.tif
SCREEN 5-17 [Process report...], Specific placement module screen example, part 2 and 3
Report text explanation, Specific placement module option
See screen example SCREEN 5-16 and SCREEN 5-17
Report text Explanation
Feed/Pick pos the feeder and pick positions of the selected (LAS/ WVM) place-
ment module
Note:
For tape feeders, the pick position is always 1; for twin-bulk-
feeders, 2 pick positions may be available.
Picked Total numbers of picked SMDs per feeder
Auto retry after pick total number of automatic pick retries per feeder that occurred
after SMD was missing immediately after pick action
align total number of automatic pick retries per feeder that occurred
after SMD was missing upon starting the align action (WVM
only)
misalign total number of automatic pick retries per feeder that occurred
after SMD could not properly be aligned
scroll area
MIS
User Reference Manual 4022 591 96082
5-22 FCM Multiflex 02.02
TABLE 5-8
Manual pick error FCM Multiflex stopped after having reached the auto
retry limit
total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
missing before
align
FCM Multiflex stopped after having reached the auto
retry limit
total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
misalign
FCM Multiflex stopped after having reached the auto
retry limit
total number of manual pick retries per feeder
after SMD could not properly be aligned
missing after
align
FCM Multiflex stopped immediately after the SMD was
lost after performing the alignment action
total number of manual pick retries per feeder
retained after
place
FCM Multiflex stopped immediately after the SMD was
still present on the nozzle after trying to place
it on the board
total number of manual pick retries per feeder
not placed
(skipped)
total number of picked SMDs per feeder that are not placed
(dumped) as a result of selecting [Skip action] or [Skip board]
in the [Error
Recovery] dialogue
Misalign
details
(= Automatic +
manual retries)
X-offset the measured X-offset exceeded the X-reject level as specified
in the SMD info file
Y-offset the measured Y-offset exceeded the Y-reject level as specified
in the SMD info file
Phi-offset the measured Phi-offset exceeded the Phi reject level as speci-
fied in the SMD info file
Width the measured SMD width exceeded the width (tolerance) as
specified in the SMD info file
Length the measured SMD length exceeded the length (tolerance) as
specified in the SMD info file
Not measurable the laser align or vision system was not able to measure the
SMD that was picked up (LAS: a laser error occurred during the
align process; WVM: not all sides of the SMD within the cam-
eras field of view)
Lead count the vision system detected that the number of leads measured
on the North/South and/or East/ West side of the SMD are not
the same (WVM only)