FCM_User Reference Manual.pdf.pdf - 第116页

MIS User Re ference Manual 4022 5 91 96082 5-24 F CM Mult ifl ex 02.02 Report text expl anation, B VM option T ABLE 5- 10 fcm05 25a.tif SCREE N 5-1 8 [Proc ess r eport... ] , BVM screen e xample Report text Explanation B…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-23
MIS
TABLE 5-9
Report text Explanation
Misalign details
(= Automatic +
manual retries)
(continued)
Lead pitch the vision system detected that the distance
between all individual leads on one (or more)
side(s) of the component is not within the
required tolerance (WVM only)
Lead width the vision system detected that the SMDs
lead width is out of tolerance (WVM only; for
asymmetric SMDs with only one lead at one
side, as lead pitch does not exist in this
case)
Coplanarity the vision system detected that not all individ-
ual leads on one (or more) side(s) of the SMD
are positioned in-line (for instance, one or
more leads are bent) (WVM only)
Component geometry the vision system detected that the leads on
the North/South and/or East/West side of the
SMD are not exactly opposite each other (for
SMDs with leads on all four sides only) (WVM
only)
Retry limit the number of automatic retries after which
the FCM Multiflex will stop with a pick error or
misalign error; this number is defined in the
action spec (see SCREEN 5-14)
MIS
User Reference Manual 4022 591 96082
5-24 FCM Multiflex 02.02
Report text explanation, BVM option
TABLE 5-10
fcm0525a.tif
SCREEN 5-18 [Process report...], BVM screen example
Report text Explanation
BVM - Errors Errors total number of times the BVM was unable to
measure a board
Retries total number of manual initiated BVM retries
Time lost due to
BVM errors
(hh:mm:ss)
Response total waiting-for-operator time during a BVM
error (time between occurrence of the error
and the moment the operator starts with
recovery) expressed in hh:mm:ss, where
hh = hours, mm = minutes, and ss = seconds
note that “10 seconds” is denoted as only “10”
instead of “00:00:10”
Down the total time the FCM Multiflex has stopped
due to a BVM error; expression details, see
above
BVM - Disabled
circuits
Count the total number of circuits that has been disa-
bled because of a badmark detection
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-25
MIS
Report text explanation, BI option
TABLE 5-11
fcm0526a.tif
SCREEN 5-19 [Process report...], BI screen example
Report text Explanation
BI - Errors Barcode read attempts the total number of read actions; equals the
total number of boards that passed the run-in
section
Barcode read errors the total number of times a boards barcode
could not successfully be read
Barcodes skipped the total number of times a barcode read
action was skipped