4022 591 96082 User Re ference Manual 02.02 FCM Multiflex 5-31 MIS T ABLE 5- 13 Gr aph legend Explanation Manual p ick err . ■ FCM M ul tiflex stopped after having reached the auto r et ry limit ■ total number of manual …

100%1 / 306
MIS
User Reference Manual 4022 591 96082
5-30 FCM Multiflex 02.02
Graph explanation, All modules, Averages option
fcm0527a/0529a.tif
SCREEN 5-26 [Process graph...] All modules, Averages screen examples
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used placement
modules
Placed scale for total number of placed SMDs
total number of placed SMDs per placement
module (blue circle)
Auto retries aft. pick total number of automatic pick retries per place-
ment module that occurred after SMD was
missing immediately after pick action
misalign total number of automatic pick retries per place-
ment module that occurred after SMD could not
properly be aligned
align total number of automatic pick retries per place-
ment module that occurred after SMD was
missing upon starting the align action (WVM
only)
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-31
MIS
TABLE 5-13
Graph legend Explanation
Manual pick err.
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per
placement module after SMD was missing
immediately after pick action
misalign
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per
placement module after SMD could not properly
be aligned
lost BA
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per
placement module after SMD was missing upon
starting the align action (WVM only)
lost AA
FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
total number of manual pick retries per
placement module
retained
FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying to
place it on the board
total number per placement module of manual
pick retries
skipped total number per placement module of picked
SMDs that are not placed (dumped) as a result of
selecting [Skip action] or [Skip board] in the
[Error Recovery] dialogue
MIS
User Reference Manual 4022 591 96082
5-32 FCM Multiflex 02.02
Graph explanation, All modules, Details option
fcm0530a/0531a.tif
SCREEN 5-27 [Process graph...] All modules, Details screen examples
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used placement
modules
Auto retries aft. pick total number of automatic pick retries per feeder
that occurred after SMD was missing
immediately after pick action
misalign total number of automatic pick retries per feeder
that occurred after SMD could not properly be
aligned
align total number of automatic pick retries per feeder
that occurred after SMD was miss-ing upon
starting the align action (WVM only)