MIS User Re ference Manual 4022 5 91 96082 5-50 F CM Mult ifl ex 02.02 G rap h e xpl an at ion fcm0 550a / 0551 a.ti f SCREE N 5-4 1 Process gr aph exam pl e of a traced SM D, [Absolute] mode / [PPMs] mo de Gr aph legend…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-49
MIS
the partnumber of the SMD reel that has been used for the selected SMD type
Below these informations, the process errors are displayed in bar-graphs, that
have different colours for each process error type. The amount of errors can be
read from the left Y-axis. This can either be in absolute numbers or in PPMs,
depending on the selected mode.
The number of placed SMDs are displayed in a line-graph. The amount of
placed SMDs can be read from the right Y-axis.
NOTE: The process errors that occurred on the traced SMD are displayed in bright
colours, the process errors for the other SMDs are displayed in pale colours.
The process errors are divided into auto retries and manual retries (see below).
fcm0548a.tif
SCREEN 5-39
An auto retry is a retry without operator intervention (automatic); the
maximum allowed number of auto retries is determined in the action spec,
(see SCREEN 5-16).
A manual retry is a retry by operator intervention. After the FCM Multiflex
has reached the auto retry number limit, it stops, and manual retries may be
done by the operator then. Note that only those manual retries are taken
into account for the process report that were successful at first attempt.
fcm0549a.eps
SCREEN 5-40 Action spec setting of the maximum number of auto pick retries (refires)
FEEDER 1 1 T8-M/4 T 333-222-112 SOD-80
COMMENT index coordinates are relative to pipette origin
COMMENT indx/brd /refholex/refholey/board_x /board_y
INDEX 1 3 -75.500 294.250 -81.500 138.000
INDEX 1 4 74.500 294.250 68.500 138.000
INDEX 2 3 4.500 294.250 -1.500 138.000
COMMENT pick coordinates are relative to pipette origin
COMMENT fd/pk/psh/rfr/pick_x /pick_y /pick_phi/na/prf/arf/ale/ple
PICK 1 1 1 2 19.000 77.000 90.0 1 75 55 80 80
COMMENT: In case a deviating dump position is needed enter
COMMENT: DUMP position_x position_y
COMMENT mount coordinates are in board coordinates
in this example, the number of auto(matic)
pick retries (or
refires
) is set to 2
rfr = refires
MIS
User Reference Manual 4022 591 96082
5-50 FCM Multiflex 02.02
Graph explanation
fcm0550a/0551a.tif
SCREEN 5-41 Process graph example of a traced SMD, [Absolute] mode/ [PPMs] mode
Graph legend Explanation
Errors scale for number of errors (in Absolute mode
only)
PPMs scale for number of errors per million SMDs (in
PPMs mode only)
Mod. no. position numbers of the used feeders
Placed scale for total number of placed SMDs
total number of placed SMDs per feeder (blue
circle)
Auto retries aft. pick total number of automatic pick retries per feeder
that occurred after SMD was missing
immediately after pick action
misalign total number of automatic pick retries per feeder
that occurred after SMD could not properly be
aligned
align total number of automatic pick retries per feeder
that occurred after SMD was missing upon
starting the align action (WVM only)
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-51
MIS
TABLE 5-23
Controls
Select [Trace component...] from the [Troubleshooting] menu
The following dialogue screen will appear:
fcm0546a.tif
SCREEN 5-42
Enter the item code of the SMD(s) you want to be traced; this is the SMD’s
reference identification as used in the action spec. It usually corresponds with
the code engraved on the board (next to the SMD).
NOTE: The item code can also be found on the Product Item Code Plot-drawing
which was generated by PPS.
Manual pick err. FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
misalign
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD could not properly be aligned
lost BA
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
lost AA
FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
total number of manual pick retries per feeder
retained
FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying
to place it on the board
total number per feeder of manual pick retries
skipped total number per feeder of picked SMDs that are
not placed (dumped) as a result of selecting
[Skip action] or [Skip board] in the [Error
Recovery] dialogue