FCM_User Reference Manual.pdf.pdf - 第144页

MIS User Re ference Manual 4022 5 91 96082 5-52 F CM Mult ifl ex 02.02 ■ If the board consist s of a n umber of circ uits, enter th e spe cific circuit num ber on which the b ad plac ements were found. If the b oa r d is…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-51
MIS
TABLE 5-23
Controls
Select [Trace component...] from the [Troubleshooting] menu
The following dialogue screen will appear:
fcm0546a.tif
SCREEN 5-42
Enter the item code of the SMD(s) you want to be traced; this is the SMD’s
reference identification as used in the action spec. It usually corresponds with
the code engraved on the board (next to the SMD).
NOTE: The item code can also be found on the Product Item Code Plot-drawing
which was generated by PPS.
Manual pick err. FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing immediately after pick
action
misalign
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD could not properly be aligned
lost BA
FCM Multiflex stopped after having reached
the auto retry limit
total number of manual pick retries per feeder
after SMD was missing upon starting the align
action (WVM only)
lost AA
FCM Multiflex stopped immediately after the
SMD was lost after performing the alignment
action
total number of manual pick retries per feeder
retained
FCM Multiflex stopped immediately after the
SMD was still present on the nozzle after trying
to place it on the board
total number per feeder of manual pick retries
skipped total number per feeder of picked SMDs that are
not placed (dumped) as a result of selecting
[Skip action] or [Skip board] in the [Error
Recovery] dialogue
MIS
User Reference Manual 4022 591 96082
5-52 FCM Multiflex 02.02
If the board consists of a number of circuits, enter the specific circuit number
on which the bad placements were found. If the board is not divided in separate
circuits, the number to be filled in is always 1.
Select [OK]
Once the item code and circuit number have been entered, the MIS system will start
searching for the SMD in the action spec.
If the entered SMD parameters are found, the process graph of the placement
module where this SMD is used will be displayed (see SCREEN 5-41).
The controls on the right of the screen have the functions:
select
[Print (F7)] or press <F7> to print the graph
select [PPMs] if you wish to display the errors in Parts Per Million
select
[Absolute] if you wish to display the absolute number of errors
select [Quit] to leave the [Production times...] menu
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-53
MIS
5.3.5 Machine Performance
5.3.5.1 [Reports] > [Machine performance...]
TABLE 5-24 Quick Reference
fcm0552a.tif
SCREEN 5-43 [Machine performance...] screen example
Actions select [Functions...] in the MIS pull-down menu
select [Reports]
select [Machine performance...]
Conditions supervisor access level
order active
Information FCM Multiflex module involved (e.g. Base, Transport etc.)
FCM Multiflex machine identification and serial no.
MIS period name + start/stop date/time
action spec name
order name
report date/time
display of all machine errors by
error type
number of errors
error cause
operator response time
down time (excluding operator response time)
display of all servo warnings by
number of tracking warnings
drift specification
Display Options -