FCM_User Reference Manual.pdf.pdf - 第224页

Pr oduc t Ch ang e Ov er User Re f eren ce Manu al 4022 591 960 82 6-32 FCM M ult ifle x 02.02 ■ Look at th e B VM monit or t o d etermine if th e r ectangl e fit s e xactl y th e ba dmark (see FIGURE 6 -11 FI GURE 6-11 …

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-31
Product Change Over
The [Teach Badmark] menu appears (see below)
SCREEN 6-23
Smallest Enclosing Rectangle
Select [Smallest Enclosing Rectangle]
Look at the monitor:
For spot-type badmarks, check if the rectangle is completely covered by the
badmark; that means that the badmark should be larger than the rectangle
FIGURE 6-10 Controlling the smallest enclosing rectangle for spot-type badmarks
For fiducial-type badmarks, proceed with the following points:
Product Change Over
User Reference Manual 4022 591 96082
6-32 FCM Multiflex 02.02
Look at the BVM monitor to determine if the rectangle fits exactly the badmark
(see FIGURE 6 -11
FIGURE 6-11 Selecting the smallest enclosing rectangle for fiducial-type badmarks
If not, act as follows:
Select
[Move]
Adjust left line with arrow keys or mouse and scroll bar
Adjust top line
Select
[Resize]
Adjust bottom line
Adjust right line
Key operating movements:
TABLE 6-12
NOTE: Adjustment via the graphical mouse control is also possible, but control is
less exact.
Algorithm
There are 2 options for the badmark detection algorithm:
TABLE 6-13
arrow keys slow movement (0.05 mm)
Home/End keys quick left/right movement (0.2 mm)
Page Up/Page Down keys quick up/down movement (0.2 mm)
binary quick but less reliable
interpolation slower but more reliable
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-33
Product Change Over
Select [Algorithm] by typing b
SCREEN 6-24
For spot-type badmarks, select
[Badmark] in [Spot Recognition]
For fiducial-type badmarks, decide from the BVM monitor image which is the
best one to use and select
[Binary] or [Interpolation]
NOTE: The quicker binary algorithm requires a good image, no spots and damages.
If you are in doubt, make some trial measurements.
The following parameters are affected by the selected algorithm:
[Threshold]
[Tolerance]
[Polarity]
[Smallest Enclosing Rectangle]
[Area of Interest]
[Area of Fiducial]
This is indicated in the description of the parameter concerned.