FCM_User Reference Manual.pdf.pdf - 第249页

4022 591 960 82 Us er Reference Man ual 02.02 FC M Multif lex 6-57 Pr oduc t Ch ang e Ov er 6.7.3.2 P arameter Description compone nt type This param eter con sists o f th e two sub-par ame ters compon en t n ame or comp…

100%1 / 306
Product Change Over
User Reference Manual 4022 591 96082
6-56 FCM Multiflex 02.02
6.7.3 Large Symmetric Components
6.7.3.1 Package Types
From software FC5.0 on, the FCM Multiflex package type database contains the SMD
info files for large symmetric component types as well. Here, the component
package types PLCC, QFP, SSOP, SOJ, TSOP, TSSOP, SO and VSO are involved.
FIGURE 6-23 gives an example of such an SMD info file.
FIGURE 6-23 Example of a large symmetric component type SMD info file
You can edit these files in the same way you are used to do with the normal size
components SMD info files, using the [Edit SMD Info] function.
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-57
Product Change Over
6.7.3.2 Parameter Description
component type
This parameter consists of the two sub-parameters component name or component
code.
component name
component code
component length
component width
check leads ns
Field type Quoted string
Range
a
a. The option sign “|” indicates that one out
of the listed parameters is to be used.
“PLCC” | “QFP” | “SSOP” | “SOJ” | “TSOP” | “TSSOP” | “SO” | “VSO” |
“CLC_1210”
Description General name of the component type
Field type Integer
Range 1 - 19
Description Component’s name equivalent, represented as a number
Field type Real
Range 0 - 25.000 (mm)
Description Component’s nominal length
Field type Real
Range 0 - 25.000 (mm)
Description Component’s nominal width
Field type Integer
Range TRUE | FALSE(TRUE = 1; FALSE = 0)
Description If TRUE, then the vision system will check the number of leads at
both the north/south side as stated in the <number of leads at side
north/south> field.
If FALSE, then the vision system will count the number of leads at
each north/south side and check that both numbers match.
For components that don’t have north/south leads by component type
definition, this field is ignored.
Product Change Over
User Reference Manual 4022 591 96082
6-58 FCM Multiflex 02.02
number of leads at side north/south
check leads ew
number of leads at side east/west
check thickness
component thickness
light level
Field type Integer
Range 0 - 100
Description Number of leads at each north/south side
Field type Integer
Range TRUE | FALSE
Description If TRUE, then the vision system will check the number of leads at
both the east/west side as stated in the <number of leads at side
east/west> field.
If FALSE, then the vision system will count the number of leads at
each east/west side and check that both numbers match.
For components that dont have east/west leads by component type
definition, this field is ignored.
Field type Integer
Range 0 - 100
Description Number of leads at each east/west side
Field type Integer
Range TRUE | FALSE
Description If TRUE, then the vision system will use the value that is stated in the
<component thickness> field.
If FALSE, then the vision system will use a default value as defined
for the concerned component type.
Field type Real
Range 0.000 - 6.000 (mm)
Description Component thickness
Field type Integer
Range 0 - 100
Description Light level setting for an adequate measuring of the component.