FCM_User Reference Manual.pdf.pdf - 第257页

4022 591 960 82 Us er Reference Man ual 02.02 FC M Multif lex 6-65 Pr oduc t Ch ang e Ov er ▼ LIGHT_LEVEL ▼ SKEW_DETEC TION [NOR TH] [SOUTH] [NOR TH/SOUTH] [EAST] [WEST] [EAST/WEST] Th ese par am eter bl o cks s pecify t…

100%1 / 306
Product Change Over
User Reference Manual 4022 591 96082
6-64 FCM Multiflex 02.02
FIGURE 6-25 Body dimensions, height and depth
REJECT_LEVEL
BODY_TOLERANCE
[2D]
This parameter block defines the illumination that will be used in a 2D vision meas-
urement.
ILLUMINATION_TYPE
Field type Real
Range > 0 (mm resp. degrees)
Description <reject_level_X> <reject_level_Y> <reject_level_Phi>
The maximum allowed deviation from the ideal pick position in X-, Y-
and Phi-direction.
Field type Real
Range > 0 (mm)
Description <footprint_X_tolerance> <footprint_Y_tolerance>
Absolute dimensions for the tolerance on the size of the component
in X- and Y-direction.
Field type String
Range REFLECTION
Description The used illumination type.
package_height
package_depth
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 6-65
Product Change Over
LIGHT_LEVEL
SKEW_DETECTION
[NORTH]
[SOUTH]
[NORTH/SOUTH]
[EAST]
[WEST]
[EAST/WEST]
These parameter blocks specify the lead information parameters for the various lead
groups and the vision processing parameter settings.
Lead Information Parameters
Lead information parameters are the parameters that define a lead group. If more
than one lead group exists (package class: SPECIAL), then these parameters are
numbered with an index to indicate which group of the parameter is valid.
The numbering sequence must be from left to right for the NORTH and SOUTH
descriptions and from top to bottom for EAST and WEST descriptions (FIGURE 6-26).
Field type Integer
Range 0 - 100 (%)
Description Defines the light level for REFLECTION in percentage of the maxi-
mum light level.
Field type Boolean
Range ON or OFF (= Default)
Description Checks whether the NORTH-SOUTH leads are perpendicular to the
EAST-WEST leads (lead-bending check).
Product Change Over
User Reference Manual 4022 591 96082
6-66 FCM Multiflex 02.02
FIGURE 6-26 Numbering sequences as used within the lead information blocks
Each lead-side block can contain the following parameters:
NB_OF_LEAD_GROUPS
NB_OF_LEADS (NB_OF_LEADS_i if i>1)
GROUP_OFFSET (GROUP_OFFSET_i if i>1)
LEAD_WIDTH (LEAD_WIDTH_i if i>1)
LEAD_PITCH (LEAD_PITCH_i if i>1)
LEAD_LENGTH (LEAD_LENGTH_i if i>1)
LEAD_TOLERANCE (LEAD_TOLERANCE_i if i>1)
An SMD info file may contain more than one lead group parameter block. Which
blocks are present depends on the package class, e.g. an SMD info file for a
component of the SOT package class contains a [NORTH] and a [SOUTH] block. Each
parameter block consists of two sets of sub-parameters.
NB_OF_LEAD_GROUPS
NB_OF_LEADS
Field type Integer
Range 0 - 255
Description Defines the number of lead groups (group of leads with identical
pitch) for a component side.
Field type Integer
Range 1 - 255
Description Defines the number of leads in a specific lead group.
North
South
West
East
1
1
1
1
1
1