00194340-01 - 第35页
Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP) Edition 04/2006 → Locate pin module on lane where pin support is necessary. Connect the 3 tubin g from control unit to pin module according…

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
→ Adjust tubing length according to lane number where pin module(s) will be located.
NOTE
Tubing length need adjustment according to location the pin module is used on lifting table to
avoid interference to conveyor’s rail. Please refer Appendix 7.1 for recommendation of tubing
length. Color alphabetical coded option plate shown is meant to be a reference when table in
Appendix is used.
Up to maximum of 3 pin modules can be used on each placement areas.
Figure 2.5-1 Air interface tubing to pin module
2-30

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
→ Locate pin module on lane where pin support is necessary. Connect the 3 tubing from
control unit to pin module according to the port abbreviation shown in Figure 2.5-2.
Figure 2.5-2 Connect air from air distributor to pin module
CAUTION
Pins is designed to be very sensitive to contact force during teaching of PCB profile,
therefore special care has to be taken in consideration during handling. Lock all the pins at
lowest position after used for storage.
2-31

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
3 Operation instructions
3.1 Overview of operations
Upon full retrofit of AVSP on SIPLACE placement machine, AVSP can automatically adapt to
any PCB profile within a few steps.
teach the pin module
Users only need to
to adapt to the PCB profile using sample PCB.
The pin module can always be re-teach easily by following the similar steps.
3.2 PCB profile teaching operations
→ Turn ON machine power and you could see the SIPLACE main page on screen. Press
start key to reference run the machine.
NOTE
Turn air supply’s valve ON if you have shut OFF during retrofitting.
Reference run is a must for AVSP to functions correctly.
Figure 3.2-1 SIPLACE main page
3-32