Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP) Edition 04/2006 1 Figure 5.2-2 Teach pendant (1) Teach pendant (Item No.: 03031428-0 1) 5.3 Spare parts for control unit & others 1 Fig…

100%1 / 54
Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
5.2 Spare parts for control unit & others
2
1
4
3
5
6
Figure 5.2-1 Spare parts for control units
(5) AVSP Control Unit Vacuum Valve Assembly (Item No.: 03047481-01)
(6) Vacuum Pump MINI L14 (Item No.: 03031306-01)
(7) AVSP Controller Unit Unclamp Solenoid valve (Item No.: 03031310-01)
(8) AVSP Controller Unit Up/Down Solenoid valve (Item No.: 03031311-01)
(9) AVSP Controller Unit Vacuum Switch Assembly (Item No.: 03031312-01)
(10) Air operated valve (Item No.: 03031304-01)
5-41
Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
1
Figure 5.2-2 Teach pendant
(1) Teach pendant (Item No.: 03031428-01)
5.3 Spare parts for control unit & others
1
Figure 5.3-1 Spare parts for air service unit
(2) Air Filter AF30-03 (Item No.: 03039711-01)
5-42
Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
6 Troubleshooting Guide
6.1 Not possible to enter teaching mode
Check if the AVSP option is enabled. Status LED will light ON continuously if AVSP is
enabled or blinks shortly if vacuum is disabled.
Check if machine’s reference run completed. Reference run of machined is required to
perform teaching function correctly.
6.2 Teaching mode: Pin(s) not reset to lowest
stroke
Check the all tubing connection and the air supply. The air supply should be 5.0 bar.
Check if manual override on solenoid valve is activated. Make sure it is not activated.
Manual
Override
Figure 6.2-1 Manual override for solenoid valve
6-43