6.3 Teaching mode: Pin(s) not moves up
Check the all tubing connection and the air supply. The air supply should be 5.0 bar.
Check if manual override on solenoid valve is activated. Make sure it is not activated.
Check the maintenance program scheduled for pin module. Greasing on internal seal
may be necessary.
6.4 Production mode: Pin(s) moves freely/ not
clamped
Check the all tubing connection and the air supply. The air supply should be 5.0 bar.
Check if manual override on solenoid valve is activated. Make sure it is not activated.
If everything seems all right, activate teaching mode and then follow by aborting it.
Repeat this a few times. Check again. If problem persists, send the pin module unit back
for repair.