Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP) Edition 04/2006 7 Appendix 7.1 Tubing length recommendation 7.1.1 Single conveyor placement area 1, right fixed 7.1.2 Single conveyor place…

Retrofit Instructions & User’s Manual / Automatic Vacuum Support Pins (AVSP)
Edition 04/2006
6.3 Teaching mode: Pin(s) not moves up
→ Check the all tubing connection and the air supply. The air supply should be 5.0 bar.
→ Check if manual override on solenoid valve is activated. Make sure it is not activated.
→ Check the maintenance program scheduled for pin module. Greasing on internal seal
may be necessary.
6.4 Production mode: Pin(s) moves freely/ not
clamped
→ Check the all tubing connection and the air supply. The air supply should be 5.0 bar.
→ Check if manual override on solenoid valve is activated. Make sure it is not activated.
→ If everything seems all right, activate teaching mode and then follow by aborting it.
Repeat this a few times. Check again. If problem persists, send the pin module unit back
for repair.