20
Attach the solenoid valve [03110893-xx], the Cable and the COT insert switch (two loop) to
the Valve mounting plate [03109013‑xx] with the screws ISO 10642 - M4x8-A2-70
[03082822‑xx].
Connect the wires from the machine to the solenoid valve.
Plug in the Tube Insert Module LOC1 [03102152-xx] to the input port of the valve.
Fix the valve assembly to the Top panel cover 2 [03106303-xx].
Secure the cover onto the frame.
E-Insert Right Sub-Assembly (without Fastening) [03111455-xx]
Qty Description Part Number
1 E-series Table Insert Right Sub-Assembly 03104512-xx
2 ISO 8735- 8 x 28-B-ST 03016102-xx
2 ISO 7093-1 - 6 - 200 HV - A2 03022709-xx
1 ISO 7090 - 8 - 200HV - A2 03090874-xx
2 ISO 4762 - M 6 x 30-A2-70 03042576-xx
1 ISO 4762 - M 8 x 30-A2-70 03042587-xx
Install the E-series table insert
right sub-assembly [03104512-xx]
onto the frame with the fasteners
shown.
 NOTICE!
The M6 screws and one of the
ISO8735 dowels are inserted
from below.
.
Assembly Instructions E by SIPLACE
Location 1 Upgrade Kit 04/2017
2 Installing the Location 1 Upgrade Kit [03113225‑xx] (FixedtoMov-
2.4 Connection to solenoid valve
21
2.4 Connection to solenoid valve
Connect the marked tube [03111719-xx] to the bottom right port of the solenoid valve.
Connect the unmarked tube [03111719-xx] to the bottom left port of the solenoid valve.
Use the tube [03111720-xx] to connect the top right port of the solenoid valve to the rear port
of the cylinder.
Use the short tube [03111718-xx] to connect the top left port to the Tee Joint.
Use the tube [03111722-xx] to connect the Tee Joint to the front port of the cylinder.
Connect the 4mm tube from the push-out cylinder of [03104512-xx] to the 4mm output of the
Tee Joint.
2 Installing the Location 1 Upgrade Kit [03113225‑xx] (FixedtoMov-
2.5 Final Work
Assembly Instructions E by SIPLACE
Location 1 Upgrade Kit 04/2017
22
2.5 Final Work
Tighten the cable ties securing the two tubes behind the tape cutter.
Install the covers.