Service Works Sensor Location Overview 2.9.1 Sensor Location SIPLACE JTF-M 82 Service Manual SIPLACE JEDEC Tray Feeder 2.9 2 . 9 S e n s o r L o c a t io n O v e r v ie w Sensor Location Overview 2.9.1 2 . 9 . 1 S e n s …

100%1 / 122
Service Works
2.8.5 Troubleshooting Charts SIPLACE JTF-S Troubleshooting SIPLACE JTF-S
Service Manual SIPLACE JEDEC Tray Feeder 81
The return pusher does not suc-
cessfully push a tray into the
feeder base.
There may be an obstruction on
the conveyor.
Remove the obstruction and
press the Reset button.
The return cylinder may not have
operated properly.
Check to see if the return
pusher is firing.
Check to see if the return
pusher is extending all of the
way.
Check the pneumatic adjust-
ments for the return cylinder.
Check the valve block for the
cylinder.
Check the cylinder itself.
The spring in the return mecha-
nism may be worn out.
Check the spring, and re-
place it if necessary.
The die are knocked out of the
tray as it returns to the stack.
The tray may be slowing down
too quickly during the “return
slow- down” delay.
Check the return slow-down
delay setting.
The return pusher may be oper-
ating too quickly.
Check the pneumatic adjust-
ments for the return cylinder.
Problem Possible Cause Solution
Service Works
Sensor Location Overview 2.9.1 Sensor Location SIPLACE JTF-M
82 Service Manual SIPLACE JEDEC Tray Feeder
2.9
2.9 Sensor Location Overview
Sensor Location Overview
2.9.1
2.9.1 Sensor Location SIPLACE JTF-M
Sensor Location SIPLACE JTF-M
The following drawings show the approximate locations of the sensors used to control the feeder:
Sensor locations - Top of feeder
1. "Magazine Slot" sensor (Pos440)
2. "Tray in magazine present" sensor (Pos520)
Sensor Locations - Bottom of Feeder
1. "Elevator Up” sensor (Pos480)
2. "Elevator Down” sensor (Pos480)
3. “Door lock” sensor (Pos500) (Behind the side panel)
Service Works
2.9.2 Sensor Location SIPLACE JTF-S Sensor Location Overview
Service Manual SIPLACE JEDEC Tray Feeder 83
2.9.2
2.9.2 Sensor Location SIPLACE JTF-S
Sensor Location SIPLACE JTF-S
The following drawings show the approximate locations of the sensors used to control the feeder:
Sensor Locations Conveyor / Main Air Connection
1. "Stop at End" sensor (Pos460)
2. "Forward Slow- Down" sensor (Pos440)
3. "Return Slow- Down" sensor (Pos510)
4. Maintenance internal pressure test connection
5. Normal dry air input
Sensor locations - Top of feeder
1. „Stack Full“ sensor (Pos520)
2. "Stop at Stack“ sensor (Pos520)
3. „Thin“ Tray sensor (Pos440)
4. „Thick“ Tray sensor (Pos440)