00197543-01_SM_JTF-S_ JTF-M_en - 第84页

Service Works Sensor Location Overview 2.9.2 Sensor Location SIPLACE JTF-S 84 Service Manual SIPLACE JEDEC Tray Feeder Sensor locations - Bottom feeder 1. „Elevat or Up“ sens or (Pos480) 2. "Door lock“ sensor (behin…

100%1 / 122
Service Works
2.9.2 Sensor Location SIPLACE JTF-S Sensor Location Overview
Service Manual SIPLACE JEDEC Tray Feeder 83
2.9.2
2.9.2 Sensor Location SIPLACE JTF-S
Sensor Location SIPLACE JTF-S
The following drawings show the approximate locations of the sensors used to control the feeder:
Sensor Locations Conveyor / Main Air Connection
1. "Stop at End" sensor (Pos460)
2. "Forward Slow- Down" sensor (Pos440)
3. "Return Slow- Down" sensor (Pos510)
4. Maintenance internal pressure test connection
5. Normal dry air input
Sensor locations - Top of feeder
1. „Stack Full“ sensor (Pos520)
2. "Stop at Stack“ sensor (Pos520)
3. „Thin“ Tray sensor (Pos440)
4. „Thick“ Tray sensor (Pos440)
Service Works
Sensor Location Overview 2.9.2 Sensor Location SIPLACE JTF-S
84 Service Manual SIPLACE JEDEC Tray Feeder
Sensor locations - Bottom feeder
1. „Elevator Up“ sensor (Pos480)
2. "Door lock“ sensor (behind the side panel)(Pos500)
3. "Tray Thin-Thick“ switch
4. „Lift Cylinder Down“ sensor (under the cover and
“Tray Stack Cylinder”)(Pos450)
5. „Lift Cylinder Up“ sensor (under the cover and “Tray
Stack Cylinder”)(Pos450)
6. „Elevator Down“ sensor (Pos480)
Sensor Locations – Conveyor
1. "Forward Slow- Down“ sensor (Pos440)
2. "Return Slow -Down“ sensor (Pos510)
3. Maintenance Internal Pressure test connection
4. Normal Dry Air Input
5. „Stop at End“ sensor (Pos460)
Maintenance
Introduction
Service Manual SIPLACE JEDEC Tray Feeder 85
3
3 Maintenance
Maintenance
3.1
3.1 Introduction
Introduction
This feeder requires a minimum of maintenance. However, these few required maintenance steps are
important. If they are ignored, performance may suffer and the feeder may wear out prematurely.
All bearings used in the feeder are sealed, and do not require lubrication. The feeder uses dry run chains,
and these should not be lubricated.
3.2
3.2 Tools for Maintenance
Tools for Maintenance
The following tools are recommended when servicing the JEDEC feeder:
For Europe and Asia:
Allen wrenches in inch-sizes can be purchased easily in online-shops for motorcycle equipment. Those
inch-sizes are mainly used for US- and Japanese motorcycles as well.
Conversions for commonly used dimensions
NOTICE
Contamination of components
Any lubrication applied to mechanical parts in the feeder could potentially migrate and / or out-
gas, which could contaminate the components being fed. Use only the speci fi ed lubricants.
Qty. Description Used for
1 Tool, Allen wrench, .050 -5/16 Gearbox and couplings
1 Fitting, straight union, 4mm To extend existing air ling tubing.
1 Screwdriver, Vishay spectrol Potentiometer adjustment
1 Tubing, poly 4mm x 2.5 mm, 1m length To extend existing air tubing.
1 SIPLACE JTF-M maintenance CD ROM Maintenance instructions, troubleshooting
1 Power supply, 24V DC, 60W, enclosed Power to feeder on bench.
2 Pin, elevator locating, SIPLACE JTF-M Check alignment of elevator bars.
1 Shim, guide block alignment Set height of conveyor belt.
1 Maintenance kit, air pressure gauge Checking input air pressure.
Inch mm
1/16" 1,58mm
5/64" 1,98mm
3/32" 2,38mm
1/8" 3,18mm
5/32" 3,98mm
3/16" 4,77mm
1/4" 6,35mm
5/16" 7,94mm
3/8" 9,5 mm