YSM10安装调整(eng) - 第106页

For Ser v ice E n gineer Service Information SI1610004E -000= YSM10_Proced ures for the adjustmen ts required after installing a machine 106/107 11.3.8 Multi camera – “ 󴥬󴫐 ” adjustm ent (Optio n) If the mac hine is equ…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
105/107
When the machine is equipped with a “6-Digital MultiC
11. Select “6-Digital MultiC.
Figure 158
12. Make the head suck the light adjuster with its light gray surface facing down.
13.
[Execute] .
Attach the light adjuster to the head according to the message and perform the adjustment.
14. Remove the light adjuster.
After completing the adjustment, press the [Emergency Stop]
and remove the light adjuster
from the head. Then [Vac. ON/OFF] to turn off the vacuum operation.
If the 304A (315A) 󳬹󳴵 (that the machine is not equipped with) was attached manually for the
adjustment, remove it and put the original 󳬹󳴵 back to the head.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
106/107
11.3.8 Multi camera 󴥬󴫐 adjustment (Option)
If the machine is equipped with an optional multi camera, perform the “󴥬󴫐” adjustment for the
camera.
Required 󳬹󳴵: Type 303A (314A) 󳬹󳴵 (For SOP)
Required component: Use either of the following.
16-pin 󵪼󵮄 QFP
Part No. (MCH_SETUP)
WITHOUT a sticker
(KW8-M880A-00 / 󵪼󵮄 QFP 16P)
No.10 (QFP16_P0.8)
Use either of the
󵪼󵮄 QFPs.
WITH a sticker
(KHY-M880A-00 / 󵪼󵮄 QFP 16P ASSY)
No.34
(QFP16_P0.8_WHITE)
Table 48
:
When a 16-pin 󵪼󵮄 QFP with a sticker is used, select the Part No. 34 and tick the “Negative Rec.
checkbox.
1.
[011 Multi Camera] on the CalibSm main menu and select “󴥬󴫐” from
“Adjust Item”.
Figure 159
2.
[Move to Set Pos.] and change the 󳬹󳴵 to the 303A (314A) 󳬹󳴵.
If the machine is equipped with an ANC:
The 󳬹󳴵 of the head to be adjusted is changed to 303A (314A) 󳬹󳴵 automatically and the
head moves to above the front-side feeder bank.
If the machine is NOT equipped with an ANC:
The head moves to above the front-side feeder bank. Put the machine into the Emergency
Stop state and attach the 303A (314A) 󳬹󳴵 to the head by hand.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
107/107
3. Make Head 1 suck a 16-pin 󵪼󵮄 QFP.
4.
[Execute] to start the adjustment.
5. Save the measured data.
Make sure that the measured values fall within the specification and save the data.
<Specified value>
Item
Specified value
Camera Angle
0.000 +/- 0.100 degrees
󴥬󴫐 X
25.635
m (Fixed)
󴥬󴫐 Y
23.814 ~ 25.014
m
Dual Rec Offset
-0.050 ~ +0.050mm
Table 49
6. When the machine is equipped with two (2) multi cameras, change the setting of the camera
to 6-Digital MultiCand perform the adjustment continuously.
Caution:
When the 󳬹󳴵 was manually attached to the head, make sure to remove the 󳬹󳴵 after the
adjustment.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/