YSM10安装调整(eng) - 第51页

For Service Engineer Service Information SI1610004E - 000 = YSM10_Procedures for the adjustments required a fter installing a machine 51 / 107 5.7 “ A MF I ndex” and “VgC hart” 5.7.1 About “A MF Index”  AMF Index 1 INDE…

100%1 / 107
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
50/107
5.6.2 “ACP-Chip” adjustment for the multi camera
1. Select the “AutoRun/Measure” tab on the ACP-Chip window.
Figure 66
2. Change the setting of Adjust Camera to 5-Digital MultiC (Multi camera).
3.
[All] .
Perform the ACP-Chip adjustment for the Multi camera in the same manner as the adjustment for
the Scan camera.
Items to be adjusted
Digital 5(6) _All the heads of the camera (Main 󳬹󳴵) Precision Zigzag parameter (X, Y)
Digital 5(6) _All the heads except for the Head 1 of the camera (Main 󳬹󳴵)
Precision Parallel parameter (X, Y)
4. Perform the ACP-Chip adjustment for the 6-Digital MultiC continuously.
If the mahcine is equipped with the multi cameras both on the front and the rear side of it, change
the setting of Adjust Camera to 6-Digital MultiC, and perform the ACP-Chip adjustment.
5. Perform the ACP-Station adjustment.
After completing the ACP-Chip adjustment, perform the ACP-Station adjustment with a 304A
(315A) 󳬹󳴵 and a 68-pin 󵪼󵮄 QFP.
See 6. ACP-Station adjustment (with a 󵪼󵮄 QFP and the Multi camera) for the method.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
51/107
5.7 AMF Index” and “VgChart”
5.7.1 About “AMF Index”
AMF Index 1
INDEX 1 (Total) --- CPK (Process Capability)
It indicates if the value obtained by the formula below meets the upper limit standard value (USL).
Deviation with single head at a single angle (3σ) + “Average distance from the center (
)”
Figure 67
AMF Index 2
It quantifies the variation of mounting position at a single angle against the variations of all the four
angles (0, 90,180 and 270 degrees).
If it falls below 1.0, feeding back the correctio values is effective.
Figure 68
Only the
value can be improved by the feedback.
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
52/107
5.7.2 Check the “VgChart” window
1.
[VgChart] .
The chart window is automatically created.
Figure 69
2. Check the mounting state for each head on the chart window.
Figure 70
<When the “AMF index 1” value falls below 1.0>
Check the chart window to determine which head is the causal factor that the “AMF Index 1” does
not meet the specification.
Analyze the chart and perform the further adjustment if needed.
* See How to analyze the VgChart for how to interpret the graphs.
* See 11.Basic adjustments required when “AMF index 1” falls below 1.000 for the adjustment
procedure.