For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
95/107
“Lightness” adjustment for the Sideview camera
Perform the “Lightness” adjustment for the sideview camera continuously.
1. Remove the 󳬹󳴵 from Head 1.
:
The “Lightness” adjustment for the sideview camera is performed WITHOUT a 󳬹󳴵 on the head.
2. Select “Lightness” from “SideView Camera”.
Figure 140
3.
[Execute] .
As no light adjusters are used for the Lightness adjustment of the sideview camera, just
[Execute]
.
Make sure that the values in the “Result” and the “Bit” fields fall within the specification, and save
the data.
If the values fall within the specification, fill in the values on the check sheet.
[Specified value]
Color of the light adjuster
Tolerance of the measured value
Bit value
Side view
Not used
180 +/- 5
32 - 448
Table 42
[
]
When the Bit value does not meet the specification, check the following.
Is the lighting environment affecting the adjustment result?
Is the lighting condition normal? (Are all the LEDs lit?)
:
As the upper limit of the specified Bit value is the warning value, the adjustment can be performed even
when the value exceeds the specified value.
If the measured result exceeds 448 (the 7/8 of the limit value), it may attribute to the deterioration of the
lighting device. It is recommended to replace the lighting. (Limit value of the Bit value: 511)
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
96/107
11.3.4 Scan camera -󴥬󴫐 adjustment
The Scan camera is the main component recognition camera for YSM10.
Required 󳬹󳴵: Type 303A (314A) 󳬹󳴵 (For SOP)
Required component: 16-pin 󵪼󵮄 QFP (with a sticker on the back) / KHY-M880A-00
16-pin 󵪼󵮄 QFP
Part No. (MCH_SETUP)
WITHOUT a sticker
(KW8-M880A-00 / 󵪼󵮄 QFP 16P)
No.10 (QFP16_P0.8)
Use either of
the 󵪼󵮄 QFP
WITH a sticker
(KHY-M880A-00 /
󵪼󵮄 QFP 16P ASSY)
No.34 (QFP16_P0.8_WHITE)
Table 43
1.
[010 Scan camera] on the CalibSm main menu and select 󴥬󴫐 from
Main Camera”.
Figure 141
:
When the 16-pin 󵪼󵮄 QFP with a white sticker on the back of it is used for the adjustment, make sure
to tick the “Negative Rec.” checkbox.
2.
[Move to Set Pos.] .
If the machine is equipped with an ANC:
The 󳬹󳴵 of the head to be adjusted is changed to 303A (314A) 󳬹󳴵 automatically and the
head moves to above the front-side feeder bank.
If the machine is NOT equipped with an ANC:
The head moves to above the front-side feeder bank. Put the machine into the Emergency
Stop state and attach the 303A (314A) 󳬹󳴵 to the head by hand.
该文档极速PDF编辑器生成
如果想去掉该提示,请访问并下载
http://www.jisupdfeditor.com/
For Service Engineer
Service Information
SI1610004E-000= YSM10_Procedures for the adjustments required after installing a machine
97/107
3. Shift the 16-pin 󵪼󵮄 QFP 1.5mm to 2.0mm and make the 󳬹󳴵 suck the 󵪼󵮄 QFP.
Shift the 16-pin 󵪼󵮄 QFP from the 󳬹󳴵 center 1.5 to 2.0mm to the Y-direction (the direction of
the leaf spring) when setting it to the 󳬹󳴵 tip.
Figure 142
4. Perform the recognition test.
After attaching the 󵪼󵮄 QFP to the 󳬹󳴵,
[Rec.Test] to perform the recognition
test, and check if the shift amount of the result is within 1.5mm to 2.0mm.
If the shift amount is less than 1.5mm, set the 󵪼󵮄 QFP again.
Figure 143
:
If a recognition error occurs, change the setting of the Search Area (mm) of the Part information
No.10 QFP16_P0.8” and “No.34 QFP16_P0.8_WHITE” to 5.0mm on the [Parts] [Vision] window.
Figure 144
5.
[Execute] to start the adjustment.
6. Save the measured data.
Make sure that the measured values fall within the specification and save the
data.
<Specified value>
Item
Specified value
Camera Angle
0.000 +/- 0.500 degrees
󴥬󴫐 X
26.000
m
󴥬󴫐 Y
25.500 ~ 26.500
m
Dual Rec Offset
-0.052 ~ 0.052 mm
Table 44
The value of “dY” should
fall within 1.5 to 2.0.