YSi-V_Ope_E - 第102页

A-3 Appendix 3. UPS (Uninterr uptible Power Supply) 3.1 Safety precaution 3.1.1 Precautions when shipping or expor ting the UPS When shipping the machine equipped with a UPS, alw a ys remove the UPS from the mac hine and…

100%1 / 110
A-2
Appendix
2. Connection between machines
This inspection machine unloads a board when it receives a conveyance permission signal from the next
process machine, and then sends a conveyance permission signal to the previous process machine to request
another board.
The interface connector labeled "NEXT INTERFACE" connects to the next process machine (downstream
machine), and the interface connector labeled "PREVIOUS INTERFACE" connects to the previous process
machine (upstream machine). Both connectors are AMP 206043-1 (14-pin receptacle).
Each connector is installed inside the left and right cover on the lower rear of the machine. For the dual lane,
the connector is provided at two locations of each lane. The connectors are classified into lane 1 and lane 2.
14
11
12
7
4
8
3
1
7
12
4
8
1
14
11
3
Machine-to-machine connection example
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Preceding process machine Next process machineThis machine
DC +24V
DC +24V
Relay output
Input
Input
Input
Input
Relay output
PNP input
PNP input
NEXT INTERFACE connector
AMP 206043-1
(14-pin receptacle)
PREVIOUS INTERFACE connector
AMP 206043-1
(14-pin receptacle)
23504-M9-00
n
Board transfer signal specifications
· PREVIOUS INTERFACE · NEXT INTERFACE
Pin No. Signal specifications Pin No. Signal specifications
1 Board transfer permit 1 Board transfer permit
2 Board transfer permit COM 2 Board transfer permit COM
3 Board transfer request 3 Board transfer request
4 Board transfer request COM 4 Board transfer request COM
5 Inspection result OK (pass)
6 Inspection result OK (pass) COM
7 Inspection result NG (fail)
8 Inspection result NG (fail) COM
A-3
Appendix
3. UPS (Uninterruptible Power Supply)
3.1 Safety precaution
3.1.1 Precautions when shipping or exporting the UPS
When shipping the machine equipped with a UPS, always remove the UPS from the machine and carefully
pack it in a separate box.
Take appropriate measures so that the UPS storage temperature does not exceed the rated range (-15 to +50°C).
If the storage temperature exceeds +50°C, the UPS might malfunction or dilute sulfuric acid might leak from
the UPS battery.
When the UPS is left stored for more than three months, the UPS battery may become unusable. Be sure to
recharge the UPS battery once every three months unless the machine has been installed shortly after shipping.
The UPS used at this time for YAMAHA machines does not fall under the Export Trade Control Ordinance.
3.1.2 Disposing of used battery after replacement
This UPS uses a lead battery, so do not discard it as incombustible waste. Dispose of it properly in compliance
with legal regulations in your country. If any point is unclear about the disposal method, please consult our
sales office or representative.
3.1.3 Safety precautions
When using the UPS, take the following precautions to ensure safety. Failure to follow these safety precautions
may result in serious accidents.
n
Do not connect any other than the specified unit to the UPS output receptacle.
Increased load capacity may shorten the UPS backup time or prevent the UPS from providing sufficient backup power if
an overload occurs or cause the YSi-V power to turn off. For details, refer to the instruction manual that comes with the
UPS.
n
Immediately replace the battery when no longer usable.
Dilute sulfuric acid may leak out from the UPS battery if used when worn down, causing smoke or fire.
n
Do not disassemble, repair and modify the UPS except when replacing the battery.
Electrical shock or fire may result.
n
Do not touch the UPS battery if fluid is leaking out of the inside.
Loss of eyesight or burns may result, if battery fluid gets in eyes or comes in contact with skin. Immediately wash
liberally with pure water and consult a physician for proper treatment.
n
If unusual sounds, odor or smoke is coming out from the UPS, or if battery fluid leaks out,
immediately turn off the YSi-V power switch and the UPS power switch.
Continuous operation under such conditions may cause fire. If this happens, immediately turn off the YSi-V power switch
and also all breakers located inside the rear panel of the YSi-V. Then turn off the UPS power switch.
After checking no power is supplied to the YSi-V and UPS, contact our sales office or representative..
n
Securely ground the UPS during recharging.
When recharging a UPS which is being stored, always connect the UPS to the ground pin of the AC input plug.
n
Install the UPS facing correctly in the YSi-V.
Battery fluid may leak out if the UPS is installed facing the wrong way.
n
Do not block the air intake and outlet vents on the UPS.
Blocking the air vents causes the internal temperature to rise excessively, resulting in malfunctions, breakdowns or fire.
n
Do not use the UPS in locations at high temperatures above 40°C.
The UPS battery may wear down quickly or cause fire. This may also cause breakdown or malfunction.
A-4
Appendix
n
Avoid installing or storing the UPS in the following locations.
· Airtight locations or locations where inflammable gases or corrosive gases are present.
· Outdoor locations
· Dusty locations
Using in the above locations may cause fire and must be avoided.
n
Do not get the UPS wet and do not splash with water.
Electrical shock or fire may result.
n
Do not short the UPS battery terminals.
Burns or fire may result. Use caution even when handling a used battery since electrical energy still remains inside the
battery.
n
Do not throw the battery into fire or do not destroy the battery.
The battery may explode or the internal dilute sulfuric acid might leak out.
n
When recharging the UPS battery during storage, always connect to the power outlet of the
specified AC power voltage (50/60Hz).
Connecting to a power outlet of different AC voltage may cause fire.
n
Do not insert a metallic object into the power output connector.
Electrical shock may result.
n
Do not insert the AC input plug into the power output connector.
The UPS may be damaged.