1. Before operation
This section describes how to reset an emergency stop status and clear an error that the YSi-V experiences.
Be sure to read thoroughly before operating the YSi-V.
1.1 Canceling emergency stop
Follow these steps to cancel emergency stop.
1
Check safety.
Before continuing the procedure, check the surrounding area for safety.
2
Release the emergency stop button.
When the emergency stop button is pressed, turn it clockwise to release it
3
Press the [READY] button.
Pressing the [READY] button on the operation panel turns on the servomotors.
[READY] button
[READY] button
23200-M9-00
1.2 Clearing an error
If an error occurs a buzzer sounds and a warning screen appears. To clear the error, use the following steps.
1
Turn off the buzzer.
Press the [BUZZER OFF] button on the error screen to turn off the buzzer.
Error screen
24200-M9-00
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make a note of the
description.
3
Clear the error screen.
After removing the cause of the error, press the [OK] button on the error screen to clear the error screen.

2-2
2
Basic operation
2.
Starting and ending the YSi-V and software operation
2.1 Starting
Following a pre-operation inspection, use the following procedure to start up the YSi-V and software.
w
WARNING
ALWAYS BE SURE TO PRESS THE EMERGENCY STOP BUTTON BEFORE INSPECTING THE YSI-V INTERIOR.
n
Pre-operation inspection
Check item Check content
Air
Check that the upper part of the air pressure gauge on the YSi-V reads 0.40
MPa (between 0.39 MPa and 0.41 MPa).
Power supply
Check that the specified power is connected to the power supply box located
behind the front lower right panel of the YSi-V.
Safety cover Check that the covers are closed.
Conveyor
Check that no chips or debris are on the conveyor.
Check that the conveyor units do not interfere with each other, such as push-up
pins under the conveyor rails.
Marker pen (option) Check that the pen is attached correctly.
1
Turn the main switch ON.
The main switch is located at the lower right on the YSi-V front panel. Turn the switch clockwise to the
ON position.
Main switch
Main Switch
ONON
OFF
OFF
24201-M9-00
2
Perform return-to-origin.
1. Close the safety cover.
2. Cancel the emergency stop state and press the [READY] button.
3. Pressing the [Yes] button on the screen starts the return-to-origin operation.
Return-to-origin
24201-M9-00

2-3
2
Basic operation
2.2 Ending
To end the YSi-V operation, follow these steps.
1
Press the [Off] button in the button area.
[Off] button
24204-M9-10
2
The power-off confirmation dialog appears. Follow the instructions on the screen.
Power-off screen
24205-M9-00
e
Pressing the emergency stop button exits the YSi-V application program and the Windows.
c
CAUTION
Use the emergency stop button when “having to immediately stop the YSi-V operation in an emergency situation”
and “instructed to do so in a dialog”. Do not use it while the YSi-V operates normally.
3
Turn off the main switch on the YSi-V.
When the YSi-V gets ready for turning off, turn the main switch counterclockwise on the YSi-V.
c
CAUTION
If you turn off the power without following the correct sequence, the data may be damaged.