YSi-V_Ope_E - 第69页
4-5 4 Maintenance n Camera Check Station c CAUTION The inspector has the Camera Check Station illustrated below in its body. The Camera Check Station has some checking jigs such as the light adjuster/3D checking plates t…

4-4
4
Maintenance
2. Maintenance list
n
Maintenance list
The following maintenance procedure codes are used:
S: Inspection C: Cleaning L: Lubrication E: Replacement ( ): Procedure required only when a problem exists.
n
NOTE
Example) C (E) is indicated in the Others, Air, Mist filter, and Filter items of the table shown below. This indication means
that the part needs to be replaced if the contamination cannot be removed as a result of the filter cleaning work.
Section Unit name Check items Weekly Monthly 3 Mon. 6 Mon. 1 Year 2 Years 3 Years
Servo
controlled axes
X-axis
Ball screw SCL
Guide SCL
Y-axis
Ball screw SCL
Guide SCL
CZ-axis (option) Ball screw SCL
Conveyor
Board transport unit
Board sensor SC
Board clamp S
Conveyor belt SC E
W-axis
Ball screw CL
Guide CL
Hexagon spline CL
Vision system
Lighting unit
Optical camera
Camera lighting
unit
C
Others
Base unit Filter C (E)
Air/mist filter Filter, Cup C (E)
Main unit
(inside)
Controller
Filter
(For Type HS2
specification only)
C (E)
UPS UPS battery *1
Option Marker pen unit Cam block CL
*1: The UPS battery will wear down, reaching the end of its service life. The service life slightly differs depending on the usage
environment (ambient temperature, etc.). As a general guide, the UPS battery should be replaced with a new one after the UPS
has been operated for 2.5 years even under the optimal conditions.
For detailed information on how to replace the UPS battery, see the user's manual that comes with the UPS.
n
Periodical maintenance
The accuracy adjustment/lighting adjustment (periodical maintenance), using dedicated jigs is recommended for about
once an year, depending on the machine operating hours and operating environment.
The periodical maintenance is performed by our service engineers.
Contact your sales representative for details.

4-5
4
Maintenance
n
Camera Check Station
c
CAUTION
The inspector has the Camera Check Station illustrated below in its body. The Camera Check Station has some
checking jigs such as the light adjuster/3D checking plates to check the camera condition automatically and
periodically. DO NOT use alcohol upon cleaning these light adjuster/3D checking plates. If the alcohol be applied to,
it would make the surface of plate change in color and interfere the correct checking. As such, dust with a lens
blower brush or wipe gently with dry lint-free cloth upon cleaning.
Camera Check Station
Light adjuster (Bi-color)
Light adjuster (white)
3D Checking plate
Light adjuster (Bi-color)
[YSi-12 Camera Check Station] [YSi-V Camera Check Station (3D/optional)]
53457-M9-00

4-6
4
Maintenance
3. Preparing for maintenance tasks
3.1 Consumable parts
The term "consumable parts" in this manual indicates parts subject to continual wear during use causing
gradual loss of functions.
The following parts are classified in this manual as consumable parts and should be replaced as needed during
maintenance.
n
Consumable parts list (optional parts)
Product Name Parts List Designation Parts No.
Conveyor belt (for single lane) BELT 1, CONVEYOR KLT-M9127-00X
Conveyor belt (for dual lane) BELT 1, CONVEYOR KKT-M9127-00X
Air filter element FILTER ELEMENT KLC-M8506-00X
Oil mist filter element MIST FILTER ELEMENT KLC-M8507-00X
Air intake fan filter FILTER,CP FAN KLF-M115J-00X
Filter for controller FILTER KLC-M421L-00X
UPS battery BATTERY,UPS2 LG0-M53H8-01X
c
CAUTION
• Parts (part numbers) listed in this manual are current as of the time this manual was issued.
• When placing an order, always contact us to obtain the latest information.
• Part numbers are subject to change without notice. Please contact our sales representative before ordering.