00192377-02 - 第100页
2 Retrofitting Instruct. S-23 HM t o SW V 502. xx incl. RV 6-DLM1 Head (O ption) SIPLACE S -23 HM 2.8 Sequence: M odifying Hardware 07/01 Issue 100 Å Mou nt the cov er on the vacu um gene rator (2 socket he x hea d cap s…

SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
99
2
Fig. 2.8.18 Installing Vibrat. Dampers (Retrofit Kit); Making Connection to Vacuum Board
Key:
1. 4 Rubber-metal vibration dampers (enclosed package from retrofit kit)
2. Velcro-type fastener (enclosed package from retrofit kit)
3. Ribbon cable "Vacuum board" (present on the new head)
4. Strain relief bow on the socket connector (removed for "Conversion board, small axis")
5. 2 terminal strips
6. Round cable "Revolver head" (tachometer, motor) presnt on new head)
7. Pneumatic hoses, compressed air feed to the vacuum generator
8. Connection of the silicone hoses
Å Connect the 5 compressed air feeders - in correct order (number is on the hose) - to the vac-
uum generator and the blast unit (see: Fig. 2.8.18 -> 7).
Å Connect the sets of 2 thin silicone hoses to the vacumm board in the correct order (see: Fig.
2.8.18 -> 8).
Å Connect the 2 thick silicone hoses to the vacuum generator in the correct order.
1
5
7
2
8
3
4
6

2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.8 Sequence: Modifying Hardware 07/01 Issue
100
Å Mount the cover on the vacuum generator (2 socket hex head cap screws M2.5;
size 2).
Å Mount the new head cover of the 6-segment revolver head from the retrofit kit.
Take note of: The difference between the cover of the 6-segment head and 12-segment head
is scarcely visible.
Take note of: The item number of the 6-segment head cover is 00329003-01.
2.8.8 Option: Installing Nozzle Changer for 6-Segment Head, RV6 Standard
NOTE:
If you install the optional MTC during the upgrading, you have to install the nozzle changer MTC.
In this case, proceed on the basis of the "Retrofitting instructions MTC on S-25 HM" (Item no. see:
Section 2.7). 2
DANGER
As for all other installation steps related to upgrading, the machine must be turned OFF and iso-
lated from the mains, especially for all work in the vicinity of the cutter.
In addition, the compressed air feeder at the main valve of the compressed air unit in the machine
frame must be turned OFF and the compressed air lines bled by actuating the needle valve on the
compressed air unit.
Never reach into the cutter from above or below. Even when the machine is OFF, you can still in-
jury yourself on the blades of the cutter.
Secure the machine conscientiously as described in the chapter "Locking the Machine..." in the
User Manual to prevent it from being turned back ON without authorization. 2
2
2.8.8.1 De-installing: Nozzle Changer for 12-Segment Head (RV12 Standard)
Do the following whenever a 6-segment revolver head has been installed during the course of the
upgrading. This head requires the nozzle changer RV6 Standard from the retrofit kit. 2
NOTE:
S-23 HM machines that are upgraded during the Siemens Dematic commissioning already have
NO nozzle changer upon receipt in Bruchsal. In this case, proceed with the section "Installing ...". 2

SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
101
CAUTION
Make certain that now screws or other hardware fall into the cutter during the following de-instal-
lation work. 2
WARNING
While retrofitting, also make certain that the DANGER symbol and the DANGER text are placed
on the cover of the cutter (see: Section 2.5). 2
Å On the bottom of the nozzle changer, loosen the electrical and pneumatic connections (see:
Fig. 2.8.19), incl. cable tie on the nozzle changer (see: Fig. 2.8.20).
Å Remove the 12-segment nozzle changer (RV12 Standard):
Undo the 2 socket hex head cap screws M4 above the spacer bolts (as shown in Fig. 2.8.19).
Lift out the nozzle changer.