FX-3R Maintenance Guide 5-8 Rev. 1.00  XL specification Figure 5-5-3-5 Sensor Amp lifier with XL Specification <Setting procedure> 1) Change the SET/RUN change-over switch g to the “SET” mode. 2) Press the operati…

100%1 / 251
FX-3R Maintenance Guide
5-7
Rev. 1.00
5-5-3. Adjusting the Sensitivity of the WAIT/STOP/C-OUT Sensor
L specification
<Changing the output>
The output change-over setting is changed from LO (output is turned ON when the light is received)
to DO (output is turned ON when the light is interrupted).
1) Keep the [FUNC/CANCEL] button pressed for 3 sec. or longer.
2) Select
with the [+] or [] button. (Digital indicator on amplifier, )
3) Pressing the [AUTO/OK] button will complete the output change-over setting. (Note: When the
above indicator is left without any operation, the indicator is returned to the normal indication.)
Figure 5-5-3-1 Sensor Amplifier
<Percentage tuning>
Specify a percentage (%) based on the current light receiving level. This level is determined to the
set value.
Driven rail can be located at any position during percentage tuning setting.
The set value is determined to “60%”.
1) Press the [AUTO/OK] button once
momentarily.
Figure 5-5-3-2 [AUTO/OK] Button
2) Set a threshold value level percentage
with the [+] or [] button.
CAUTION: At this time, do not shut
down the sensor.
Figure 5-5-3-3 Setting of Threshold Value
The threshold value is 60%.
3) Press the [AUTO/OK] button.
“Pcnt good” is indicated when the tuning
has been completed.
Figure 5-5-3-4 Completion of Tuning
If an error occurs during tuning, take the actions shown below.
If an error is shown during tuning, press the [FUNC/CANCEL] button, and then press the
[CANCEL] button. Review the status, and then perform the percentage tuning again or restart the
tuning.
Do not put any workpiece during tuning.
Every time the auto width adjustment is performed, the sensor amplifier is then reset. 60%-set
value is changed according to each transport width.
FX-3R Maintenance Guide
5-8
Rev. 1.00
XL specification
Figure 5-5-3-5 Sensor Amplifier with XL Specification
<Setting procedure>
1) Change the SET/RUN change-over switch g to the “SET”
mode.
2) Press the operation key i to display the operation mode
setup indication (indication is “0-op”). Press the triangle
button i to set the dark ON (don).
3) Press the operation key i to display the detection function
mode setup indication (1-Fn). Press the triangle button i to
set the standard mode (Stnd).
4) Press the square button of the operation key i to display
the threshold value teaching level setup indication (3-tL)
and press the triangle button i to set “40P”.
5) Press the square button of the operation key i to display
the MODE key setup indication (5-Md). Press the triangle
button i to set the power tuning run mode (PtUn).
6) Press the square button of the operation key i to display
the power tuning target value setup indication (PL). Press
the triangle button i to set “100”.
7) Press the yellow button of the operation key i to display
the external input setup indication (A-rM). Press the triangle
button i to set the teaching without transmission
workpiece (thrU).
c
RUN indicator 1 CH
(Orange)
d Main digital display (Red)
e RUN indicator 2 CH
(Orange)
f Sub-digital display (Green)
i Operation key
h Channel change-over switch
g SET/RUN change-over switch
j Lock lever
Change to the
SET mode.
Figure 5-5-3-6 SET Mode
Figure 5-5-3-7 Operation Mode
Figure 5-5-3-8 Detection
Function Mode
Figure 5-5-3-9 Threshold Value
Teaching Level
Figure 5-5-3-10 MODE Key
Setup
Figure 5-5-3-11 Power Tuning
Target Value
Figure 5-5-3-12 External Input
Setup
FX-3R Maintenance Guide
5-9
Rev. 1.00
<Power tuning procedure>
1) Change the SET/RUN change-over switch g to the “RUN”
mode.
2) Set the auto width to “610 mm”. Keep the square button of the operation key i pressed for 3
sec. or longer to perform the power tuning.
At this time, pay special attention so that a portion between the transport rails does not interfere
with the light emitted from the optical fiber suitable for the amplifier being operated.
Change to the RUN
mode.
Figure 5-5-3-13 RUN Mode