fx3r.pdf - 第89页
FX-3R Maintenance Guide 8-7 3) When mounting the antenna array, mount it so that the positional relationship is as follows. Note that it is not allowed to reuse the conductive tape (HX 0 02680000). UP Tightening directio…

FX-3R Maintenance Guide
8-6
8-1-7. Replacing the Antenna of the Replacement Table (For Intelli trolley)
1) Disconnect the cable from the connector of the antenna array.
Antenna array
40073664
RFID JOINT CABLE ASM
40079659
Figure 8-1-7-1 Replacement Table when Viewed from the Front (Feeder Insertion Side)
2) Remove the screws (6 pcs.) securing the antenna array.
Antenna array
40073664
Conductive tape
HX002680000
Shield bracket 60
40081207
Figure 8-1-7-2 Antenna Array Assembling Drawing
Rev. 1.00

FX-3R Maintenance Guide
8-7
3) When mounting the antenna array, mount it so that the positional relationship is as follows.
Note that it is not allowed to reuse the conductive tape (HX002680000).
UP
Tightening direction
Make the tape matched
with the lower end position.
Shield bracket 60
40081207
Antenna array
40073664
Conductive tape
HX002680000
Figure 8-1-7-3 Cautions on Antenna Array Assembly
4) After the replacement has been completed, connect the antenna to the mounter or Intelli trolley
pool and make sure that the CH∗ LED on the MPC connected flashes.
Rev. 1.00

FX-3R Maintenance Guide
8-8
8-2. Bank and Replacement Table for Mechanical Feeder
8-2-1. Overall Drawing
40063859
Drive cylinder
40047264
Bank lifter RS
40047249
Drive bracket
E2708729000
Driver bracket (30)
40047265
Bank lifter LS
Figure 8-2-1-1 Overall Drawing
Rev. 1.00