00191332-01.pdf - 第112页
User Manual Test Program SITEST Software Version 405.xx Issue 01/99 3 - II

User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
3 - I
Table of Contents
Page
Calibration Functions
3.1 Preparation for the Performance of the Calibration Functions . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Complete Calibration of the Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 PCB Camera Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4 RV Camera Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 Calibration of the Machine Zero Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.6 Verification of the Calibration Tool Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.7 Calibration of the IC Camera (SIPLACE 80F4/80F5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.8 Calibration of the IC Nozzle Changer (SIPLACE 80F4/80F5) . . . . . . . . . . . . . . . . . . . . . . . 17
3.9 Calibration of the RV Nozzle Changer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5) . . . . . . . . . . . . . . . . . . . . . . . . 25
3.11 Calibration of the Coplanarity Laser Module (SIPLACE 80F4/80F5) . . . . . . . . . . . . . . . . . 27
3.12 Measuring the Position of PCB Reference Corner I
(and that of PCB Reference Corner II) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.13 Measuring the Pick-Up Positions of Tracks 1 and 120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
3 - II

User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99
3 - 1
3 Calibration Functions
NOTE
The heads and gantries must be referenced prior to the performance of the calibration functions.
For a complete calibration of the machine, the test program offers the possibility to start all calibration functions
from the "Calibrate entire machine" setting box with the aid of the
Calibrate machine...
functions (see section
3.2, Fig. 3.2.1).
However, it is also possible to start the calibration functions individually from the corresponding displays. The
functions for the placement stations SIPLACE 80S-20/S-23 must be performed on both
gantries.
A complete description of the performance of the individual calibration functions is contained in the respective
sections of this chapter.
To be able to correct also those constant placement offsets that, to some extent, still exist even after the calibration
has been carried out, the Test Program provides the capability to start from the setting box “Calibrate complete
machine” - using the
Fine calibration
function - the measuring program that is integrated into the Test Program.
The procedure to be followed for the fine calibration is described in chapt. 5 of these instructions.
3