00191332-01.pdf - 第113页
User Manual Test Program SITEST 3 Calibration Functions Software Version 405.xx Issue 01/99 3 - 1 3 Calibration Functions NOTE The he ads and gan tries m ust be refere nced p rior to the perform ance o f the c alibra tio…
User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
3 - II

User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99
3 - 1
3 Calibration Functions
NOTE
The heads and gantries must be referenced prior to the performance of the calibration functions.
For a complete calibration of the machine, the test program offers the possibility to start all calibration functions
from the "Calibrate entire machine" setting box with the aid of the
Calibrate machine...
functions (see section
3.2, Fig. 3.2.1).
However, it is also possible to start the calibration functions individually from the corresponding displays. The
functions for the placement stations SIPLACE 80S-20/S-23 must be performed on both
gantries.
A complete description of the performance of the individual calibration functions is contained in the respective
sections of this chapter.
To be able to correct also those constant placement offsets that, to some extent, still exist even after the calibration
has been carried out, the Test Program provides the capability to start from the setting box “Calibrate complete
machine” - using the
Fine calibration
function - the measuring program that is integrated into the Test Program.
The procedure to be followed for the fine calibration is described in chapt. 5 of these instructions.
3

3 Calibration Functions User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
3 - 2